Biomagnetic noninvasive localization of accessory pathways in Wolff-Parkinson-White syndrome
- PMID: 1721207
- DOI: 10.1111/j.1540-8159.1991.tb02798.x
Biomagnetic noninvasive localization of accessory pathways in Wolff-Parkinson-White syndrome
Abstract
It was our purpose to assess the clinical relevance of noninvasive magnetocardiographic localization of accessory pathways. Nine patients with Wolff-Parkinson-White (WPW) syndrome were studied. For all of them the site of the accessory pathway was known from invasive catheter mapping. A 37-SQUID (superconducting quantum interference device) sensor multichannel system (KRENIKON) was used, allowing synchronous registration with all channels. The site of the electrophysiological activity at the beginning of the delta wave was determined. Magnetic resonance images of the heart were obtained to correlate the biomagnetically localized activity with the anatomy. Magnetocardiographic localization of the bypass tract corresponded with catheter mapping with a spatial difference of 0-5 cm, 1.8 cm on the average, compared to the results obtained by catheter mapping. Thus, magnetocardiography is a promising new method for noninvasive localization of accessory pathways in WPW patients. This may streamline further invasive procedures.
Similar articles
-
Magnetocardiographic non-invasive localization of accessory pathways in the Wolff-Parkinson-White syndrome by a multichannel system.Eur Heart J. 1992 May;13(5):616-22. doi: 10.1093/oxfordjournals.eurheartj.a060224. Eur Heart J. 1992. PMID: 1618202 Review.
-
[Magnetocardiographic localization of an accessory pathway in patients with WPW syndrome].J Cardiol. 1990;20(1):227-39. J Cardiol. 1990. PMID: 2093756 Japanese.
-
Magnetocardiography: clinical investigations with a biomagnetic multichannel system.Physiol Meas. 1993 Nov;14 Suppl 4A:A61-8. doi: 10.1088/0967-3334/14/4a/011. Physiol Meas. 1993. PMID: 8274987
-
Non-invasive magnetocardiographic localization of ventricular pre-excitation in the Wolff-Parkinson-White syndrome using a realistic torso model.Eur Heart J. 1993 Feb;14(2):168-74. doi: 10.1093/eurheartj/14.2.168. Eur Heart J. 1993. PMID: 8449192
-
Localization of accessory pathways in the Wolff-Parkinson-White syndrome.Pacing Clin Electrophysiol. 1989 Oct;12(10):1691-705. doi: 10.1111/j.1540-8159.1989.tb01848.x. Pacing Clin Electrophysiol. 1989. PMID: 2477825 Review.
Cited by
-
Evaluation of the non-invasive localization accuracy of cardiac arrhythmias attainable by multichannel magnetocardiography (MCG).Int J Card Imaging. 1996 Mar;12(1):47-59. doi: 10.1007/BF01798116. Int J Card Imaging. 1996. PMID: 8847454
-
Biomagnetic 3-dimensional spatial and temporal characterization of electrical activity of human stomach.Dig Dis Sci. 1998 Apr;43(4):683-93. doi: 10.1023/a:1018852208687. Dig Dis Sci. 1998. PMID: 9558020
-
Accuracy of single-dipole inverse solution when localising ventricular pre-excitation sites: simulation study.Med Biol Eng Comput. 1998 May;36(3):323-9. doi: 10.1007/BF02522478. Med Biol Eng Comput. 1998. PMID: 9747572
-
The magnetocardiogram.Biophys Rev (Melville). 2024 May 29;5(2):021305. doi: 10.1063/5.0201950. eCollection 2024 Jun. Biophys Rev (Melville). 2024. PMID: 38827563 Free PMC article. Review.
-
Clinical magnetocardiography: the unshielded bet-past, present, and future.Front Cardiovasc Med. 2023 Aug 10;10:1232882. doi: 10.3389/fcvm.2023.1232882. eCollection 2023. Front Cardiovasc Med. 2023. PMID: 37636301 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources