Extremity dosimetry for radiation workers handling unsealed radionuclides in nuclear medicine departments in India
- PMID: 17220712
- DOI: 10.1097/01.HP.0000236787.25865.fb
Extremity dosimetry for radiation workers handling unsealed radionuclides in nuclear medicine departments in India
Abstract
In India, for the past five decades, whole body radiation dose of radiation workers has been monitored by means of film and thermoluminescent dosimeter (TLD) badges worn on the body. However, there are no provision/regulatory requirements to monitor doses received at the extremities, i.e., to fingers. Finger dose monitoring is essential for controlling the extremity dose limits for occupational personnel handling unsealed radioactive sources. In order to estimate the doses received in various types of procedures using unsealed sources, finger dose monitoring was carried out in 54 major institutions in the country using a specially designed plastic finger ring embedded with a TLD. The maximum finger dose of occupational workers involved in handling Tc in such activities as extraction and radiopharmacy work is 0.35 mSv GBq; during injection of radiopharmaceuticals and scintigraphy, the doses were observed to be 1 and 0.95 mSv GBq, respectively. Similarly, while handling F-FDG, the maximum doses received during dispensing, injection, and scintigraphy were 0.098, 0.324, and 0.56 mSv GBq, respectively. The maximum radiation dose received during Re/Re balloon angioplasty and while handling Sm was 3.92 and 6.5 mSv GBq, respectively. All the doses recorded were well within the prescribed limit. However, monitoring of these doses periodically would help in compiling the feedback regarding the work practices followed in institutions handling radioisotopes in the country and would also help in maintaining a record of safe work procedures while handling radioisotopes.
Similar articles
-
Finger doses for staff handling radiopharmaceuticals in nuclear medicine.J Nucl Med Technol. 2006 Sep;34(3):169-73. J Nucl Med Technol. 2006. PMID: 16951286
-
A comprehensive dose reconstruction methodology for former rocketdyne/atomics international radiation workers.Health Phys. 2006 May;90(5):409-30. doi: 10.1097/01.HP.0000183763.02247.7e. Health Phys. 2006. PMID: 16607174
-
Hand exposure to ionising radiation of nuclear medicine workers.Radiat Prot Dosimetry. 2008;130(3):325-30. doi: 10.1093/rpd/ncn057. Epub 2008 Feb 29. Radiat Prot Dosimetry. 2008. PMID: 18310609
-
An overview on extremity dosimetry in medical applications.Radiat Prot Dosimetry. 2008;129(1-3):350-5. doi: 10.1093/rpd/ncn149. Epub 2008 Apr 29. Radiat Prot Dosimetry. 2008. PMID: 18448440 Review.
-
The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions.Radiat Prot Dosimetry. 2006;119(1-4):248-54. doi: 10.1093/rpd/nci692. Epub 2006 Jul 11. Radiat Prot Dosimetry. 2006. PMID: 16835277 Review.
Cited by
-
Validation of a new protocol for ¹⁸F-FDG infusion using an automatic combined dispenser and injector system.Eur J Nucl Med Mol Imaging. 2012 Nov;39(11):1720-9. doi: 10.1007/s00259-012-2174-0. Epub 2012 Jun 28. Eur J Nucl Med Mol Imaging. 2012. PMID: 22740098
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous