Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2007 Apr;69(3):817-36.
doi: 10.1007/s11538-006-9163-z. Epub 2007 Jan 18.

A model of tracer transport in airway surface liquid

Affiliations
Comparative Study

A model of tracer transport in airway surface liquid

D J Smith et al. Bull Math Biol. 2007 Apr.

Abstract

This study is concerned with reconciling theoretical modelling of the fluid flow in the airway surface liquid with experimental visualisation of tracer transport in human airway epithelial cultures. The airways are covered by a dense mat of cilia of length approximately 6 microm beating in a watery periciliary liquid (PCL). Above this there is a layer of viscoelastic mucus which traps inhaled pathogens. Cilia propel mucus along the airway towards the trachea and mouth. Theoretical analyses of the beat cycle (smith et al., 2006b; Fulford and Blake, 1986) predict small transport of PCL compared with mucus, based on the assumption that the epithelium is impermeable to fluid. However, an experimental study (Matsui et al., 1998) indicates nearly equal transport of PCL and mucus. Building on existing understanding of steady advection-diffusion in the ASL (Blake and Gaffney, 2001; Mitran, 2004), numerical simulation of an advection-diffusion model of tracer transport is used to test several proposed flow profiles and to test the importance of oscillatory shearing caused by the beating cilia. A mechanically derived oscillatory flow with very low mean transport of PCL results in relatively little 'smearing' of the tracer pulses. Other effects such as mixing between the PCL and mucus, and significant transport in the upper part of the PCL above the cilia tips are tested and result in still closer transport, with separation between the tracer pulses in the two layers being less than 9%. Furthermore, experimental results may be replicated to a very high degree of accuracy if mean transport of PCL is only 50% of mucus transport, significantly less than the mean PCL transport first inferred on the basis of experimental results.

PubMed Disclaimer

Similar articles

Cited by

Publication types

Substances

LinkOut - more resources