Plasma-deposited tetraglyme surfaces greatly reduce total blood protein adsorption, contact activation, platelet adhesion, platelet procoagulant activity, and in vitro thrombus deposition
- PMID: 17236214
- DOI: 10.1002/jbm.a.31091
Plasma-deposited tetraglyme surfaces greatly reduce total blood protein adsorption, contact activation, platelet adhesion, platelet procoagulant activity, and in vitro thrombus deposition
Abstract
The ability of tetraethylene glycol dimethyl ether (tetraglyme) plasma deposited coatings exhibiting ultralow fibrinogen adsorption to reduce blood activation was studied with six in vitro methods, namely fibrinogen and von Willebrand's factor adsorption, total protein adsorption, clotting time in recalcified plasma, platelet adhesion and procoagulant activity, and whole blood thrombosis in a disturbed flow catheter model. Surface plasmon resonance results showed that tetraglyme surfaces strongly resisted the adsorption of all proteins from human plasma. The clotting time in the presence of tetraglyme surfaces was lengthened compared with controls, indicating a lower activation of the intrinsic coagulation cascade. Platelet adhesion and thrombin generation by adherent platelets were greatly reduced on tetraglyme-coated materials, compared with uncoated and Biospan-coated glass slides. In the in vitro disturbed blood flow model, tetraglyme plasma coated catheters had 50% less thrombus than did the uncoated catheters. Tetraglyme-coated materials thus had greatly reduced blood interactions as measured with all six methods. The improved blood compatibility of plasma-deposited tetraglyme is thus not only due to their reduced platelet adhesion and activation, but also to a generalized reduction in blood interactions.
(c) 2007 Wiley Periodicals, Inc.
Similar articles
-
Glow discharge plasma treatment of polyethylene tubing with tetraglyme results in ultralow fibrinogen adsorption and greatly reduced platelet adhesion.J Biomed Mater Res A. 2006 Dec 15;79(4):788-803. doi: 10.1002/jbm.a.30908. J Biomed Mater Res A. 2006. PMID: 16883583
-
Tetraglyme coatings reduce fibrinogen and von Willebrand factor adsorption and platelet adhesion under both static and flow conditions.J Biomed Mater Res A. 2009 Jun;89(3):791-803. doi: 10.1002/jbm.a.32085. J Biomed Mater Res A. 2009. PMID: 18496865 Free PMC article.
-
Fibrinogen adsorption, platelet adhesion and thrombin generation at heparinized surfaces exposed to flowing blood.Thromb Haemost. 2002 Apr;87(4):742-7. Thromb Haemost. 2002. PMID: 12008960
-
Fibrinogen: requirement for platelet aggregation and adhesion.Acta Univ Carol Med Monogr. 1972;53:9-16. Acta Univ Carol Med Monogr. 1972. PMID: 4598522 Review. No abstract available.
-
Mutual interaction between platelets and fibrinogen and its derivatives.Acta Univ Carol Med Monogr. 1972;53:17-20. Acta Univ Carol Med Monogr. 1972. PMID: 4275439 Review. No abstract available.
Cited by
-
In vivo two-photon microscopy reveals immediate microglial reaction to implantation of microelectrode through extension of processes.J Neural Eng. 2012 Dec;9(6):066001. doi: 10.1088/1741-2560/9/6/066001. Epub 2012 Oct 17. J Neural Eng. 2012. PMID: 23075490 Free PMC article.
-
Control of Probe Density at DNA Biosensor Surfaces Using Poly(l-lysine) with Appended Reactive Groups.Bioconjug Chem. 2018 Dec 19;29(12):4110-4118. doi: 10.1021/acs.bioconjchem.8b00733. Epub 2018 Nov 26. Bioconjug Chem. 2018. PMID: 30412384 Free PMC article.
-
Anti-inflammatory polymeric coatings for implantable biomaterials and devices.J Diabetes Sci Technol. 2008 Nov;2(6):984-94. doi: 10.1177/193229680800200628. J Diabetes Sci Technol. 2008. PMID: 19885288 Free PMC article.
-
Biocompatible and bioactive surface modifications for prolonged in vivo efficacy.Chem Rev. 2012 Mar 14;112(3):1615-32. doi: 10.1021/cr2000916. Epub 2011 Oct 18. Chem Rev. 2012. PMID: 22007787 Free PMC article. Review. No abstract available.
-
Development of plasma functionalized polypropylene wound dressing for betaine hydrochloride controlled drug delivery on diabetic wounds.Sci Rep. 2021 May 5;11(1):9641. doi: 10.1038/s41598-021-89105-7. Sci Rep. 2021. PMID: 33953292 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical