Technical Note: A comparison of a novel direct ophthalmoscope, the Optyse, to conventional direct ophthalmoscopes
- PMID: 17239196
- DOI: 10.1111/j.1475-1313.2006.00428.x
Technical Note: A comparison of a novel direct ophthalmoscope, the Optyse, to conventional direct ophthalmoscopes
Abstract
Despite the current popularity of binocular indirect ophthalmoscopy, direct ophthalmoscopes are still commonly used by clinicians for fundus examination. They are considered to be expensive, however, and it has been suggested that this cost can prevent their use by healthcare professionals in developing countries. The Optyse Lens Free Ophthalmoscope is a novel direct ophthalmoscope, without a lens focus system, that allows for comparatively inexpensive manufacture and supply. We compared the clarity of view with the Optyse to that with standard direct ophthalmoscopes, over a sequential cohort of patients with a variety of refractive errors and ocular conditions. The grade of clarity of view with the Optyse Lens Free Ophthalmoscope was less than conventional ophthalmoscopes (Wilcoxon signed rank test, p < 0.0001). This grade of clarity of view was not associated with the ametropia of the ophthalmoscopic observation (Spearman r < or = 0.03, p > or = 0.28) but was with the presence of cataracts (chi2 test, p < 0.0001) with both the Optyse and the conventional ophthalmoscopes. Despite its limitations, the retinal view with Optyse was often within acceptable clinical limits suggesting that this relatively inexpensive ophthalmoscope may have a place when cost prohibits any other type of ophthalmoscope use.
Similar articles
-
Comparison of two ophthalmoscopes for direct ophthalmoscopy.Clin Exp Ophthalmol. 2011 Jan;39(1):30-6. doi: 10.1111/j.1442-9071.2010.02403.x. Epub 2010 Oct 19. Clin Exp Ophthalmol. 2011. PMID: 20796260 Clinical Trial.
-
Indirect micro-ophthalmoscopy: intraoperative binocular indirect ophthalmoscopy with the operating microscope.Ophthalmic Surg. 1993 Jun;24(6):407-10. Ophthalmic Surg. 1993. PMID: 8336893
-
[Biomicroscopy of the fundus oculi using a 90 diopter lens].J Fr Ophtalmol. 1989;12(3):227-32. J Fr Ophtalmol. 1989. PMID: 2621306 French.
-
Better use of the ophthalmoscope.Practitioner. 1992 Feb;236(1511):161-5. Practitioner. 1992. PMID: 1598330 Review. No abstract available.
-
[Ophthalmoscopy: from an Helmholtz ophthalmoscope to adaptive optics].Vestn Oftalmol. 2007 May-Jun;123(3):52-5. Vestn Oftalmol. 2007. PMID: 17672098 Review. Russian. No abstract available.
Cited by
-
Tools and methods for cataract recognition in low-resource settings: A narrative review.PLOS Glob Public Health. 2025 May 16;5(5):e0004619. doi: 10.1371/journal.pgph.0004619. eCollection 2025. PLOS Glob Public Health. 2025. PMID: 40378109 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources