Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2007 Feb 1;99(3):300-6.
doi: 10.1016/j.amjcard.2006.08.026. Epub 2006 Dec 1.

Comparison of two- and three-dimensional echocardiography with sequential magnetic resonance imaging for evaluating left ventricular volume and ejection fraction over time in patients with healed myocardial infarction

Affiliations
Comparative Study

Comparison of two- and three-dimensional echocardiography with sequential magnetic resonance imaging for evaluating left ventricular volume and ejection fraction over time in patients with healed myocardial infarction

Carly Jenkins et al. Am J Cardiol. .

Abstract

Echocardiographic follow-up of left ventricular (LV) volumes is difficult because of the test-retest variation of 2-dimensional echocardiography (2DE). We investigated whether the accuracy and reproducibility of real-time 3-dimensional echocardiography (RT3DE) would make this modality more feasible for serial follow-up of LV measurements. We performed 2DE and RT3DE and cardiac magnetic resonance imaging (MRI) in 50 patients with previous infarction and varying degrees of LV function (44 men; 61 +/- 11 years of age) at baseline and after 1-year follow-up. Images were obtained during breath-hold and measurements of LV volumes and ejection fraction were made offline. Over follow-up, end-diastolic volume decreased from 192 +/- 53 to 187 +/- 60 ml (p <0.01), end-systolic volume decreased from 104 +/- 51 to 95 +/- 53 ml (p <0.01), and ejection fraction increased from 48 +/- 12% to 51 +/- 12% (p <0.01). MRI showed that LV mass shrank from 183 +/- 39 to 182 +/- 37 g (p <0.01). The correlation between change in RT3DE and change in MRI was greater than the correlations of 2DE with MRI for measurement of end-diastolic volume (r = 0.47 vs 0.02, p <0.01), end-systolic volume (r = 0.44 vs 0.17, p <0.01), and ejection fraction (r = 0.58 vs -0.03, p <0.01). The change in end-diastolic volume between baseline and follow-up with RT3DE (-4 +/- 20, p <0.01) was similar to that with MRI but was unrecognized by 2DE (4 +/- 19, p = 0.09). There was good test-retest and inter- and intraobserver correlation within RT3DE for volumes, ejection fraction, and mass. In conclusion, if sequential measurement of LV volumes is used to guide management decisions, 3DE appears preferable to 2DE.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources