Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2007 Feb;49(2):267-75.
doi: 10.1053/j.ajkd.2006.11.026.

Dialyzer membrane characteristics and outcome of patients with type 2 diabetes on maintenance hemodialysis

Affiliations
Comparative Study

Dialyzer membrane characteristics and outcome of patients with type 2 diabetes on maintenance hemodialysis

Vera Krane et al. Am J Kidney Dis. 2007 Feb.

Abstract

Background: Effects of dialyzer membrane characteristics on morbidity and mortality are highly controversial.

Methods: Post hoc, we analyzed data from the German Diabetes and Dialysis Study that evaluated atorvastatin in high-risk patients. Four groups were identified being constantly dialyzed with high-flux synthetic (n = 241), low-flux synthetic (n = 247), low-flux semisynthetic (n = 119), or cellulosic low-flux membranes (n = 41). Two end points were investigated: (1) a cardiovascular end point consisting of cardiac death, nonfatal myocardial infarction, and stroke and (2) death.

Results: After 4 years of follow-up, adjusted multivariate relative risks (RRs) were calculated. The RR to reach a cardiovascular end point was greater for patients dialyzed with cellulosic low-flux (RR, 2.33; 95% confidence interval [CI], 1.38 to 3.94; P = 0.002), low-flux semisynthetic (RR, 1.92; 95% CI, 1.35 to 2.73; P = 0.0003), or low-flux synthetic membranes (RR, 1.35; 95% CI, 0.99 to 1.85; P = 0.06) than for those treated with high-flux synthetic dialyzers. The likelihood to die was greater with cellulosic low-flux (RR, 4.14; 95% CI, 2.79 to 6.15; P < 0.0001), low-flux semisynthetic (RR, 2.24; 95% CI, 1.66 to 3.02; P < 0.0001), and low-flux synthetic membranes (RR, 1.59; 95% CI, 1.22 to 2.07; P = 0.0006) than with high-flux synthetic membranes. With respect to low-flux synthetic membranes, RRs of mortality for patients using cellulosic low-flux and low-flux semisynthetic membranes were 161% (RR, 2.61; 95 % CI, 1.80 to 3.79; P < 0.0001) and 41% (RR, 1.41; 95% CI, 1.07 to 1.86; P = 0.016) greater. Cellulosic low-flux membrane use was associated with an 85% (RR, 1.85; 95% CI, 1.24 to 2.76; P = 0.0025) greater RR of death than low-flux semisynthetic membranes.

Conclusion: These data suggest that biocompatibility and permeability may impact on death and cardiovascular events in hemodialysis patients with type 2 diabetes mellitus.

PubMed Disclaimer

Publication types

Substances

LinkOut - more resources