Iliac fixation inhibits migration of both suprarenal and infrarenal aortic endografts
- PMID: 17263997
- DOI: 10.1016/j.jvs.2006.09.061
Iliac fixation inhibits migration of both suprarenal and infrarenal aortic endografts
Abstract
Objective: To evaluate the role of iliac fixation in preventing migration of suprarenal and infrarenal aortic endografts.
Methods: Quantitative image analysis was performed in 92 patients with infrarenal aortic aneurysms (76 men and 16 women) treated with suprarenal (n = 36) or infrarenal (n = 56) aortic endografts from 2000 to 2004. The longitudinal centerline distance from the superior mesenteric artery to the top of the stent graft was measured on preoperative, postimplantation, and 1-year three-dimensional computed tomographic scans, with movement more than 5 mm considered to be significant. Aortic diameters were measured perpendicular to the centerline axis. Proximal and distal fixation lengths were defined as the lengths of stent-graft apposition to the aortic neck and the common iliac arteries, respectively.
Results: There were no significant differences in age, comorbidities, or preoperative aneurysm size (suprarenal, 6.0 cm; infrarenal, 5.7 cm) between the suprarenal and infrarenal groups. However, the suprarenal group had less favorable aortic necks with a shorter length (13 vs 25 mm; P < .0001), a larger diameter (27 vs 24 mm; P < .0001), and greater angulation (19 degrees vs 11 degrees ; P = .007) compared with the infrarenal group. The proximal aortic fixation length was greater in the suprarenal than in the infrarenal group (22 vs 16 mm; P < .0001), with the top of the device closer to the superior mesenteric artery (8 vs 21 mm; P < .0001) as a result of the 15-mm uncovered suprarenal stent. There was no difference in iliac fixation length between the suprarenal and infrarenal groups (26 vs 25 mm; P = .8). Longitudinal centerline stent graft movement at 1 year was similar in the suprarenal and infrarenal groups (4.3 +/- 4.4 mm vs 4.8 +/- 4.3 mm; P = .6). Patients with longitudinal centerline movement of more than 5 mm at 1 year or clinical evidence of migration at any time during the follow-up period comprised the respective migrator groups. Suprarenal migrators had a shorter iliac fixation length (17 vs 29 mm; P = .006) and a similar aortic fixation length (23 vs 22 mm; P > .999) compared with suprarenal nonmigrators. Infrarenal migrators had a shorter iliac fixation length (18 vs 30 mm; P < .0001) and a similar aortic fixation length (14 vs 17 mm; P = .1) compared with infrarenal nonmigrators. Nonmigrators had closer device proximity to the hypogastric arteries in both the suprarenal (7 vs 17 mm; P = .009) and infrarenal (8 vs 24 mm; P < .0001) groups. No migration occurred in either group in patients with good iliac fixation. Multivariate logistic regression analysis revealed that iliac fixation, as evidenced by iliac fixation length (P = .004) and the device to hypogastric artery distance (P = .002), was a significant independent predictor of migration, whereas suprarenal or infrarenal treatment was not a significant predictor of migration. During a clinical follow-up period of 45 +/- 22 months (range, 12-70 months), there have been no aneurysm ruptures, abdominal aortic aneurysm-related deaths, or surgical conversions in either group.
Conclusions: Distal iliac fixation is important in preventing migration of both suprarenal and infrarenal aortic endografts that have longitudinal columnar support. Secure iliac fixation minimizes the risk of migration despite suboptimal proximal aortic neck anatomy. Extension of both iliac limbs to cover the entire common iliac artery to the iliac bifurcation seems to prevent endograft migration.
Similar articles
-
The importance of iliac fixation in prevention of stent graft migration.J Vasc Surg. 2006 Jun;43(6):1130-7; discussion 1137. doi: 10.1016/j.jvs.2006.01.031. J Vasc Surg. 2006. PMID: 16765227
-
The association between iliac fixation and proximal stent-graft migration during EVAR follow-up: mid-term results of 154 Talent devices.Eur J Vasc Endovasc Surg. 2009 Jun;37(6):681-7. doi: 10.1016/j.ejvs.2009.03.001. Epub 2009 Mar 31. Eur J Vasc Endovasc Surg. 2009. PMID: 19345632
-
The role of aortic neck dilation and elongation in the etiology of stent graft migration after endovascular abdominal aortic aneurysm repair with a passive fixation device.J Vasc Surg. 2006 Dec;44(6):1176-81. doi: 10.1016/j.jvs.2006.08.028. J Vasc Surg. 2006. PMID: 17145418
-
Endograft accommodation on the aortic bifurcation: an overview of anatomical fixation and implications for long-term stent-graft stability.J Endovasc Ther. 2011 Aug;18(4):462-70. doi: 10.1583/11-3411.1. J Endovasc Ther. 2011. PMID: 21861731 Review.
-
Endoluminal abdominal aortic aneurysm repair: the latest advances in prevention of distal endograft migration and type 1 endoleak.Tex Heart Inst J. 2010;37(1):19-24. Tex Heart Inst J. 2010. PMID: 20200623 Free PMC article. Review.
Cited by
-
Effect of curvature on displacement forces acting on aortic endografts: a 3-dimensional computational analysis.J Endovasc Ther. 2009 Jun;16(3):284-94. doi: 10.1583/08-2667.1. J Endovasc Ther. 2009. PMID: 19642787 Free PMC article.
-
Relationship between the distal migration and length of the distal landing zone after endovascular aneurysm repair (EVAR).Surg Today. 2016 Jan;46(1):56-61. doi: 10.1007/s00595-014-1100-4. Epub 2014 Dec 25. Surg Today. 2016. PMID: 25539981
-
Preliminary 3D computational analysis of the relationship between aortic displacement force and direction of endograft movement.J Vasc Surg. 2010 Jun;51(6):1488-97; discussion 1497. doi: 10.1016/j.jvs.2010.01.058. J Vasc Surg. 2010. PMID: 20488325 Free PMC article.
-
Deformation and dynamic response of abdominal aortic aneurysm sealing.Sci Rep. 2017 Dec 18;7(1):17712. doi: 10.1038/s41598-017-17759-3. Sci Rep. 2017. PMID: 29255200 Free PMC article.
-
In vivo deformation of the human abdominal aorta and common iliac arteries with hip and knee flexion: implications for the design of stent-grafts.J Endovasc Ther. 2009 Oct;16(5):531-8. doi: 10.1583/09-2806.1. J Endovasc Ther. 2009. PMID: 19842734 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical