Controlled clinical comparison of BacT/ALERT standard aerobic and standard anaerobic blood culture bottles inoculated directly or after transport in sodium polyanethol sulfonate tubes
- PMID: 17267634
- PMCID: PMC1865855
- DOI: 10.1128/JCM.02091-06
Controlled clinical comparison of BacT/ALERT standard aerobic and standard anaerobic blood culture bottles inoculated directly or after transport in sodium polyanethol sulfonate tubes
Abstract
To assess relative performances in the BacT/ALERT blood culture system, we compared results from the direct inoculation of standard media and inoculation after the transport of blood samples in Vacutainer tubes with sodium polyanethol sulfonate. No significant differences in yields or times to detection were found for 387 clinically important isolates from 4,306 blood culture sets.
Similar articles
-
Controlled clinical comparison of VersaTREK and BacT/ALERT blood culture systems.J Clin Microbiol. 2007 Feb;45(2):299-302. doi: 10.1128/JCM.01697-06. Epub 2006 Nov 22. J Clin Microbiol. 2007. PMID: 17122016 Free PMC article.
-
Controlled clinical comparison of the BacT/ALERT FN and the standard anaerobic SN blood culture medium.J Clin Microbiol. 2004 Oct;42(10):4581-5. doi: 10.1128/JCM.42.10.4581-4585.2004. J Clin Microbiol. 2004. PMID: 15472312 Free PMC article.
-
Evaluation of BACTEC Plus aerobic and anaerobic blood culture bottles and BacT/Alert FAN aerobic and anaerobic blood culture bottles for the detection of bacteremia in ICU patients.Diagn Microbiol Infect Dis. 2012 Jul;73(3):239-42. doi: 10.1016/j.diagmicrobio.2012.03.022. Epub 2012 Apr 25. Diagn Microbiol Infect Dis. 2012. PMID: 22541787
-
Updated review of blood culture contamination.Clin Microbiol Rev. 2006 Oct;19(4):788-802. doi: 10.1128/CMR.00062-05. Clin Microbiol Rev. 2006. PMID: 17041144 Free PMC article. Review.
-
Procurement, interpretation, and value of postmortem cultures.Eur J Clin Microbiol Infect Dis. 1998 Dec;17(12):821-7. doi: 10.1007/s100960050200. Eur J Clin Microbiol Infect Dis. 1998. PMID: 10052543 Review.
Cited by
-
L. Barth Reller, M.D.J Clin Microbiol. 2012 May;50(5):1510-2. doi: 10.1128/JCM.00313-12. Epub 2012 Feb 15. J Clin Microbiol. 2012. PMID: 22337993 Free PMC article. No abstract available.
-
High medical impact of implementing the new polymeric bead-based BacT/ALERT® FAPlus and FNPlus blood culture bottles in standard care.Eur J Clin Microbiol Infect Dis. 2015 May;34(5):1031-7. doi: 10.1007/s10096-015-2319-8. Epub 2015 Feb 4. Eur J Clin Microbiol Infect Dis. 2015. PMID: 25648261
References
-
- Ellner, P. D., and C. J. Stoessel. 1966. The role of temperature and anticoagulant on the in vitro survival of bacterial in blood. J. Infect. Dis. 116:238-242. - PubMed
-
- Finegold, S. M., I. Ziment, M. L. White, W. R. Winn, and W. T. Carter. 1967. Evaluation of polyanethol sulfonate (liquoid) in blood cultures. Antimicrob. Agents Chemother. 7:692-696. - PubMed