Measuring minimum critical flow for normal breath sounds
- PMID: 17282803
- DOI: 10.1109/IEMBS.2005.1617034
Measuring minimum critical flow for normal breath sounds
Abstract
Relationship between respiratory sounds and flow has always been of interest for researchers and physicians. However, the flow-sound relationship at very low flow rate has been questionable because breath sounds must exceed a minimum flow in order to be audible and different from the background noise. This study aimed to find the minimum critical flow rates for respiratory sounds to be audible and different from background noise. Tracheal and lung sound signals of healthy subjects in two groups of adults (12 subjects) and children (9 subjects) were studied. The values of minimum critical flow were determined comparing the spectrogram of the respiratory sounds at very low flow with that of during breath hold. The values of minimum critical flow for tracheal sounds were found to be 3.7.. 1.7 ml/s/kg and 2.7 .. 1.7 ml/s/kg for adults and children, respectively. The minimum critical flows for lung sounds were found as 6.2 .. 1.8 ml/s/kg and 4.0 .. 2.9 ml/s/kg for adults and children, respectively.
Similar articles
-
A robust method for estimating respiratory flow using tracheal sounds entropy.IEEE Trans Biomed Eng. 2006 Apr;53(4):662-8. doi: 10.1109/TBME.2006.870231. IEEE Trans Biomed Eng. 2006. PMID: 16602572 Clinical Trial.
-
Lung sound spectra at standardized air flow in normal infants, children, and adults.Am J Respir Crit Care Med. 1996 Aug;154(2 Pt 1):424-30. doi: 10.1164/ajrccm.154.2.8756817. Am J Respir Crit Care Med. 1996. PMID: 8756817
-
Airflow effects on amplitude and spectral content of normal breath sounds.J Appl Physiol (1985). 1996 Jan;80(1):5-13. doi: 10.1152/jappl.1996.80.1.5. J Appl Physiol (1985). 1996. PMID: 8847331 Clinical Trial.
-
Robust respiratory flow estimation using statistical properties of tracheal sounds.Conf Proc IEEE Eng Med Biol Soc. 2005;2005:1106-9. doi: 10.1109/IEMBS.2005.1616613. Conf Proc IEEE Eng Med Biol Soc. 2005. PMID: 17282382
-
Heart sound and lung sound separation algorithms: a review.J Med Eng Technol. 2017 Jan;41(1):13-21. doi: 10.1080/03091902.2016.1209589. Epub 2016 Jul 15. J Med Eng Technol. 2017. PMID: 27420021 Review.
Cited by
-
Acoustic breath-phase detection using tracheal breath sounds.Med Biol Eng Comput. 2012 Mar;50(3):297-308. doi: 10.1007/s11517-012-0869-9. Epub 2012 Feb 24. Med Biol Eng Comput. 2012. PMID: 22362023
-
Tracheal Sound Analysis.Adv Exp Med Biol. 2022;1384:265-280. doi: 10.1007/978-3-031-06413-5_16. Adv Exp Med Biol. 2022. PMID: 36217090
-
The use of tracheal sounds for the diagnosis of sleep apnoea.Breathe (Sheff). 2017 Jun;13(2):e37-e45. doi: 10.1183/20734735.008817. Breathe (Sheff). 2017. PMID: 29184596 Free PMC article. Review.
LinkOut - more resources
Full Text Sources