Nitroglycerin-induced coronary vasodilation in cardiac transplant recipients. Evaluation with in vivo intracoronary ultrasound
- PMID: 1728486
- DOI: 10.1161/01.cir.85.1.69
Nitroglycerin-induced coronary vasodilation in cardiac transplant recipients. Evaluation with in vivo intracoronary ultrasound
Abstract
Background: Coronary artery vasomotion is altered after cardiac transplantation. The impact of accelerated transplant coronary atherosclerosis and myocardial rejection on vasomotion is not well understood. Intravascular ultrasound is a new imaging method with the ability to study real-time changes in coronary artery dimensions.
Methods and results: Epicardial coronary artery response to nitroglycerin was studied in 32 cardiac transplant recipients (age, 47 +/- 11 years) 3 weeks to 10 years after transplantation with intracoronary ultrasound. Cross-sectional luminal area and diameter were measured at a fixed position in the left anterior descending artery immediately before and every 30 seconds for 5 minutes after 0.4 mg of sublingual nitroglycerin. Cross-sectional area increased from a baseline of 13.1 +/- 3.9 mm2 to 15.8 +/- 3.9 mm2 at maximal vasodilation; luminal diameter increased from 4.0 +/- 0.6 mm to 4.5 +/- 0.6 mm. This increase reached statistical significance (p less than 0.001) at 1.5 minutes after administration of nitroglycerin; mean maximum increase occurred at 4.5 minutes (24% for cross-sectional area and 11% for luminal diameter). Patients with biopsy-proven mild or moderate concurrent rejection had a significantly blunted vasodilatory response versus the nonrejection group (9% versus 27% for cross-sectional area, p less than 0.04), although a vasodilatory effect was still present. Nitroglycerin response was well preserved in patients up to 10 years after transplantation; however, there was a trend toward a decreased response in patients studied immediately after transplantation (21% versus 29%, p = 0.37). Coronary intimal thickness, as measured by ultrasound, had no impact on the vasodilatory response (R = 0.23, p = 0.34).
Conclusions: Vasodilatory response to nitroglycerin in cardiac transplant recipients is attenuated during episodes of cardiac rejection. This response is preserved in long-term survivors and is independent of the degree of intimal thickening. Intravascular ultrasound provides a new method to document real-time epicardial coronary vasomotion.
Similar articles
-
How to standardize vasomotor tone in serial studies based on quantitation of coronary dimensions?Int J Card Imaging. 1998 Dec;14(6):357-72. doi: 10.1023/a:1006076409185. Int J Card Imaging. 1998. PMID: 10453390 Review.
-
Influence of intimal thickening on coronary blood flow responses in orthotopic heart transplant recipients. A combined intravascular Doppler and ultrasound imaging study.Circulation. 1995 Nov 1;92(9 Suppl):II182-90. doi: 10.1161/01.cir.92.9.182. Circulation. 1995. PMID: 7586405
-
Discordant epicardial and microvascular endothelial responses in heart transplant recipients early after transplantation.J Heart Lung Transplant. 1998 May;17(5):487-94. J Heart Lung Transplant. 1998. PMID: 9628567
-
Intracoronary ultrasound in cardiac transplant recipients. In vivo evidence of "angiographically silent" intimal thickening.Circulation. 1992 Mar;85(3):979-87. doi: 10.1161/01.cir.85.3.979. Circulation. 1992. PMID: 1537134
-
Assessment of transplant arteriopathy by intracoronary two-dimensional ultrasound imaging and coronary flow velocity.Cathet Cardiovasc Diagn. 1995 Aug;35(4):335-42. doi: 10.1002/ccd.1810350412. Cathet Cardiovasc Diagn. 1995. PMID: 7497507 Review.
Cited by
-
Noninvasive test of nitrate-induced coronary vasomotion by 1.5-T whole-heart 3D magnetic resonance angiography using a T2-prepared SSFP sequence.Int J Cardiovasc Imaging. 2012 Oct;28(7):1707-16. doi: 10.1007/s10554-011-9999-7. Epub 2011 Dec 21. Int J Cardiovasc Imaging. 2012. PMID: 22187200
-
Intracoronary ultrasound: current state of the art.Br Heart J. 1995 May;73(5 Suppl 2):16-25. doi: 10.1136/hrt.73.5_suppl_2.16. Br Heart J. 1995. PMID: 7612393 Free PMC article. Review. No abstract available.
-
Use of intravascular ultrasound for in vivo assessment of changes in intimal thickness of angiographically normal saphenous vein grafts one year after aortocoronary bypass surgery.Heart. 1996 Oct;76(4):317-20. doi: 10.1136/hrt.76.4.317. Heart. 1996. PMID: 8983677 Free PMC article.
-
New developments in the diagnosis and management of cardiac allograft vasculopathy.Tex Heart Inst J. 1995;22(2):138-44. Tex Heart Inst J. 1995. PMID: 7647597 Free PMC article. Review.
-
How to standardize vasomotor tone in serial studies based on quantitation of coronary dimensions?Int J Card Imaging. 1998 Dec;14(6):357-72. doi: 10.1023/a:1006076409185. Int J Card Imaging. 1998. PMID: 10453390 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical