Significance of lead strength during exercise testing

Affiliations

Significance of lead strength during exercise testing

George Polizos et al. Ann Noninvasive Electrocardiol. 2007 Jan.

Abstract

Background: The aim of the study was to evaluate the contribution of relative lead strengths to exercise-induced ECG changes (ST depression) to predict the degree of myocardial ischemia as compared to the angiograms. This was accomplished by comparing the magnitude of ST depression to the ST/R ratio. Studies have shown that the diagnostic strength of a lead is directly related to the R wave amplitude and that sensitivity is significantly improved.

Methods: Three hundred patients, who underwent treadmill exercise testing and coronary angiography revealing significant coronary narrowing (> or = 70% luminal diameter narrowing), were studied, along with 150 patients clear of significant coronary artery disease (<70% luminar diameter narrowing). Our goal was to determine the correlation between the relative lead strengths, using a constructed ST/R ratio, to exercise induced ECG changes (ST depression) to predict the presence of myocardial ischemia as compared to angiographic findings. Using a cutoff of 0.1 for the ST/R ratio, our data were compared to the sensitivity and specificity of 1.0 mm ST depression.

Results: Overall sensitivity was improved for the ST/R ratio (84% vs 78%), while specificity was slightly decreased (81% vs 92%) in comparison to standard ST depression. When differentiating between R wave amplitudes, those with R wave < or = 10 mm showed significantly improved sensitivity (88% vs 54%) and a minor decrease in specificity (90% vs 92%). In those with R wave > or = 20 mm, the sensitivity of ST depression was higher (88% vs 71%) but the ST/R ratio was much more specific (88% vs 46%). No significant difference was observed when differentiating between male and female patients.

Conclusion: We found that the correction of ST depression for R wave amplitude results in improved sensitivity in patients with low R waves and specificity in patients with very tall R waves (R > or = 20 mm).

PubMed Disclaimer

Figures

Figure 1
Figure 1
Leads used for measurement.
Figure 2
Figure 2
Sensitivity and Specificity according to R wave amplitude.

Similar articles

References

    1. Hollenberg M, Go J Jr, Massie BM, et al. Influence of R‐wave amplitude on exercise‐induced ST depression: Need for a "gain factor" correlation when interpreting stress electrocardiograms. Am J Cardiol 1985;56:13–17. - PubMed
    1. Ellestad MH. Stress Testing: Principles and Practices, 3rd Edition. Philadelphia , FA Davis,1985.
    1. Mason RE, Liker I. A new system of multiple lead electrocardiography. Am Heart J 1966;31:196 - PubMed
    1. Bousfield G. Angina pectoris: Changes in electrocardiogram during paroxysm. Lancet 1918;2:457.
    1. Miranda CP, Lehmann KG, Froelicher VF. Correlation between resting ST segment changes, exercise testing, coronary angiography, and long term prognosis. Am Heart J 1991;122:1617–28. - PubMed

Publication types