Generation of improved gas linear velocities in a comprehensive two-dimensional gas chromatography system
- PMID: 17288460
- DOI: 10.1021/ac0618066
Generation of improved gas linear velocities in a comprehensive two-dimensional gas chromatography system
Abstract
A comprehensive two-dimensional gas chromatography (GC x GC) system (for convenience defined as "split flow" GC x GC), which may be operated at improved gas linear velocities in both dimensions, has been developed. The setup is formed of an apolar 30 m x 0.25 mm i.d. column connected, by means of a Y press fit, to a detector-linked 1 m x 0.1 mm i.d. polar analytical column, which passes through the (cryogenic) modulator, and to a 0.3 m x 0.1 mm i.d. retention gap, which is connected to a manually operated split valve. The latter enables the regulation of gas flows through the second analytical column [e.g., 60:40 (FID) ratio, 50:50 ratio, 40:60 (FID) ratio, etc.], in order to generate the most appropriate gas linear velocity, which is related to each specific analysis. In the pre-sent investigation, two sets of traditional and split flow GC x GC analyses were carried out on a cod liver oil fatty acid methyl ester sample by using the same temperature programs [180-250 degrees C at (a) 3 degrees C/min and at (b) 1.3 degrees C/min] and at an average first-dimension linear velocity of approximately 35.0 cm/s; thus, primary column retention times (and therefore elution temperatures) were essentially maintained. The second-dimension linear velocity was calculated to be approximately 333 cm/s in the traditional applications, while it was split valve-regulated until the most appropriate values [(a) approximately 213 cm/s; (b) approximately 264 cm/s] were attained in the alternative applications. Substantial improvements were observed and measured in the chromatography along the y-axis, while the contour plot chemical class structure was maintained.
Similar articles
-
Optimized use of a 50 microm internal diameter secondary column in a comprehensive two-dimensional gas chromatography system.Anal Chem. 2009 Oct 15;81(20):8529-37. doi: 10.1021/ac901461y. Anal Chem. 2009. PMID: 19761226
-
Enhanced resolution comprehensive two-dimensional gas chromatography applied to the analysis of roasted coffee volatiles.J Chromatogr A. 2009 Oct 23;1216(43):7301-6. doi: 10.1016/j.chroma.2009.06.056. Epub 2009 Jun 23. J Chromatogr A. 2009. PMID: 19596333
-
Evaluation of use of a very short polar microbore column segment in high-speed gas chromatography analysis.J Sep Sci. 2008 Aug;31(14):2634-9. doi: 10.1002/jssc.200800192. J Sep Sci. 2008. PMID: 18623282
-
Recent advances in flow-controlled multidimensional gas chromatography.J Chromatogr A. 2012 Sep 14;1255:24-37. doi: 10.1016/j.chroma.2012.01.027. Epub 2012 Jan 18. J Chromatogr A. 2012. PMID: 22305357 Review.
-
Comprehensive two dimensional gas chromatography review.J Sep Sci. 2009 Mar;32(5-6):883-904. doi: 10.1002/jssc.200800654. J Sep Sci. 2009. PMID: 19278007 Review.
Cited by
-
Improving peak capacity in fast online comprehensive two-dimensional liquid chromatography with post-first-dimension flow splitting.Anal Chem. 2011 Dec 15;83(24):9531-9. doi: 10.1021/ac202317m. Epub 2011 Nov 23. Anal Chem. 2011. PMID: 22017622 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous