Lessons of 30 years of total hip arthroplasty
- PMID: 1728996
Lessons of 30 years of total hip arthroplasty
Abstract
The following are lessons of 30 years of total hip arthroplasty (THA): Prosthetic components should allow for easy preoperative graphic planning with one or two templates only. Polyethylene is the weak link in THA and ought to be replaced by perfectly concentric metallic sockets and femoral heads of casted Cr/Co/Mo alloys. The operating technique should guarantee large exposure, suitable orientation of both components, and adequate fixation. Loosening is correlated with loss of bone stock and changes of the position of the implants. In case of progressive bone loss, one should reoperate already in presence of slight clinical symptoms to prevent more difficult and dangerous revisions. To evaluate objectively the outcome of THA, a combined data and roentgenographic documentation system with standardized terms and scales is necessary.
Similar articles
-
Loosening of the cemented hip prosthesis. The importance of heat injury.Acta Orthop Scand Suppl. 1986;221:1-40. Acta Orthop Scand Suppl. 1986. PMID: 3468743
-
The anthropometric total hip femoral prosthesis. Preliminary clinical and roentgenographic findings of exact-fit cementless application.Clin Orthop Relat Res. 1989 May;(242):104-19. Clin Orthop Relat Res. 1989. PMID: 2706844
-
[Clinical and radiographic results of a continuous series of 124 type Ceraver-Osteal hip prostheses with a 9-year survival analysis].Rev Chir Orthop Reparatrice Appar Mot. 1994;80(4):305-15. Rev Chir Orthop Reparatrice Appar Mot. 1994. PMID: 7740131 French.
-
[Whether bone quality matters or not in durability of total hip arthroplasty? Bone quality matters in durability of total hip arthroplasty].Clin Calcium. 2011 May;21(5):746-50. Clin Calcium. 2011. PMID: 21532126 Review. Japanese.
-
New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters.Acta Orthop Suppl. 2005 Feb;76(315):3-82. Acta Orthop Suppl. 2005. PMID: 15790289 Review.
Cited by
-
DICOM for implantations--overview and application.J Digit Imaging. 2012 Jun;25(3):352-8. doi: 10.1007/s10278-011-9416-8. J Digit Imaging. 2012. PMID: 21858592 Free PMC article.
-
Provisional results of the CLS cup using IDES.Int Orthop. 1994;18(6):363-7. doi: 10.1007/BF00187082. Int Orthop. 1994. PMID: 7698868
-
Templating Hip Arthroplasty.Open Access Maced J Med Sci. 2019 Feb 23;7(4):672-685. doi: 10.3889/oamjms.2019.088. eCollection 2019 Feb 28. Open Access Maced J Med Sci. 2019. PMID: 30894933 Free PMC article. Review.
-
Is There Any Difference Between a Spherical Marker and a Simple Coin for Hip Replacement Digital Planning?Rev Bras Ortop (Sao Paulo). 2022 Jan 24;57(4):560-568. doi: 10.1055/s-0041-1724079. eCollection 2022 Aug. Rev Bras Ortop (Sao Paulo). 2022. PMID: 35966431 Free PMC article.
-
Reliability of preoperative measurement with standardized templating in Total Knee Arthroplasty.World J Orthop. 2013 Oct 18;4(4):287-90. doi: 10.5312/wjo.v4.i4.287. eCollection 2013. World J Orthop. 2013. PMID: 24147264 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources