Determinants of stress shielding: design versus materials versus interface
- PMID: 1729005
Determinants of stress shielding: design versus materials versus interface
Abstract
Experimental studies of cementless porous-coated total hip arthroplasty indicate that a critical design variable for femoral remodeling is stem stiffness. In the long term (two years) in the canine model, other variables, including the presence, type, and placement of the porous coating, did not significantly affect the pattern of bone remodeling when tested with metallic stems. The basic pattern of bone remodeling was characterized by proximal cortical atrophy, and distal cortical and medullary bone hypertrophy. In the short term (six months), the use of low-stiffness stems altered this pattern, leading to reduced proximal bone loss, increased proximal medullary bone hypertrophy, and no distal cortical hypertrophy, suggesting that stem stiffness had a profound effect on stress shielding.
Similar articles
-
Bone remodeling in experimental total hip arthroplasty.Chir Organi Mov. 1992 Oct-Dec;77(4):413-23. Chir Organi Mov. 1992. PMID: 1297575 English, Italian.
-
Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses.Clin Orthop Relat Res. 1992 Dec;(285):13-29. Clin Orthop Relat Res. 1992. PMID: 1446429
-
Preclinical testing of total hip stems. The effects of coating placement.Clin Orthop Relat Res. 1995 Oct;(319):64-76. Clin Orthop Relat Res. 1995. PMID: 7554651
-
Cementless femoral design concerns. Rationale for extensive porous coating.Clin Orthop Relat Res. 1998 Oct;(355):189-99. Clin Orthop Relat Res. 1998. PMID: 9917604 Review.
-
Hydroxyapatite-coated tapered cementless femoral components in total hip arthroplasty.J Arthroplasty. 2007 Jun;22(4 Suppl 1):71-4. doi: 10.1016/j.arth.2007.01.019. J Arthroplasty. 2007. PMID: 17570282 Review.
Cited by
-
[Shaft lengthening in hip replacement: experimental studies on bending stiffness].Unfallchirurg. 2006 Aug;109(8):652-8. doi: 10.1007/s00113-006-1101-x. Unfallchirurg. 2006. PMID: 16838173 German.
-
Anatomic grooved stem mitigates strain shielding compared to established total hip arthroplasty stem designs in finite-element models.Sci Rep. 2019 Jan 24;9(1):482. doi: 10.1038/s41598-018-36503-z. Sci Rep. 2019. PMID: 30679467 Free PMC article.
-
Periprosthetic mineralization changes around femoral stems: a prospective 12-month study with DEXA.Skeletal Radiol. 2008 Aug;37(8):723-9. doi: 10.1007/s00256-008-0482-z. Epub 2008 May 14. Skeletal Radiol. 2008. PMID: 18478226
-
Challenges and Opportunities for Integrating Dealloying Methods into Additive Manufacturing.Materials (Basel). 2020 Aug 21;13(17):3706. doi: 10.3390/ma13173706. Materials (Basel). 2020. PMID: 32825732 Free PMC article. Review.
-
Reducing the prosthesis modulus by inclusion of an open space lattice improves osteogenic response in a sheep model of extraarticular defect.Front Bioeng Biotechnol. 2023 Dec 7;11:1301454. doi: 10.3389/fbioe.2023.1301454. eCollection 2023. Front Bioeng Biotechnol. 2023. PMID: 38130824 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources