Can magnetic resonance imaging-derived bone models be used for accurate motion measurement with single-plane three-dimensional shape registration?
- PMID: 17290431
- DOI: 10.1002/jor.20355
Can magnetic resonance imaging-derived bone models be used for accurate motion measurement with single-plane three-dimensional shape registration?
Abstract
The purpose of this study was to compare three-dimensional (3D) kinematic measurements from single-plane radiographic projections using bone models created from magnetic resonance imaging (MRI) and computed tomography (CT). MRI is attractive because there is no ionizing radiation, but geometric field distortion and poor bone contrast degrade model fidelity compared to CT. We created knee bone models of three healthy volunteers from both MRI and CT and performed three quantitative comparisons. First, differences between MRI- and CT-derived bone model surfaces were measured. Second, shape matching motion measurements were done with bone models for X-ray image sequences of a squat activity. Third, synthetic X-ray images in known poses were created and shape matching was again performed. Differences in kinematic results were quantified in terms of root mean square (RMS) error. Mean differences between CT and MRI model surfaces for the femur and tibia were -0.08 mm and -0.14 mm, respectively. There were significant differences in three of six kinematic parameters comparing matching results from MRI-derived bone models and CT-derived bone models. RMS errors for tibiofemoral poses averaged 0.74 mm for sagittal translations, 2.0 mm for mediolateral translations, and 1.4 degrees for all rotations with MRI models. Average RMS errors were 0.53 mm for sagittal translations, 1.6 mm for mediolateral translations, and 0.54 degrees for all rotations with the CT models. Single-plane X-ray imaging with model-based shape matching provides kinematic measurements with sufficient accuracy to assess knee motions using either MRI- or CT-derived bone models. However, extra care should be taken when using MRI-derived bone models because model inaccuracies will affect the quality of the shape matching results.
Copyright (c) 2007 Orthopaedic Research Society.
Similar articles
-
Sensitivity of tibio-menisco-femoral joint contact behavior to variations in knee kinematics.J Biomech. 2008;41(2):390-8. doi: 10.1016/j.jbiomech.2007.08.015. Epub 2007 Oct 24. J Biomech. 2008. PMID: 17950743
-
In vivo tibiofemoral contact analysis using 3D MRI-based knee models.J Biomech. 2004 Oct;37(10):1499-504. doi: 10.1016/j.jbiomech.2004.01.012. J Biomech. 2004. PMID: 15336924
-
Double-step registration of in vivo stereophotogrammetry with both in vitro 6-DOFs electrogoniometry and CT medical imaging.J Biomech. 2006;39(11):2087-95. doi: 10.1016/j.jbiomech.2005.06.014. Epub 2005 Aug 8. J Biomech. 2006. PMID: 16085076
-
The movement of the normal tibio-femoral joint.J Biomech. 2005 Feb;38(2):197-208. doi: 10.1016/j.jbiomech.2004.02.006. J Biomech. 2005. PMID: 15598446 Review.
-
In vivo analysis of carpal kinematics and comparative review of the literature.J Hand Surg Am. 2003 Jan;28(1):81-7. doi: 10.1053/jhsu.2003.50009. J Hand Surg Am. 2003. PMID: 12563642 Review.
Cited by
-
In vivo tibiofemoral skeletal kinematics and cartilage contact arthrokinematics during decline walking after isolated meniscectomy.Med Eng Phys. 2018 Jan;51:41-48. doi: 10.1016/j.medengphy.2017.10.014. Epub 2017 Nov 6. Med Eng Phys. 2018. PMID: 29122451 Free PMC article.
-
Measurement of an intact knee kinematics using gait and fluoroscopic analysis.Knee Surg Sports Traumatol Arthrosc. 2011 Feb;19(2):267-72. doi: 10.1007/s00167-010-1190-5. Epub 2010 Jun 19. Knee Surg Sports Traumatol Arthrosc. 2011. PMID: 20563558
-
High validity of measuring the width and volume of medial meniscal extrusion three-dimensionally using an MRI-derived tibial model.J Exp Orthop. 2020 Jan 3;7(1):1. doi: 10.1186/s40634-019-0216-2. J Exp Orthop. 2020. PMID: 31900597 Free PMC article.
-
Implementation of discrete element analysis for subject-specific, population-wide investigations of habitual contact stress exposure.J Appl Biomech. 2010 May;26(2):215-23. doi: 10.1123/jab.26.2.215. J Appl Biomech. 2010. PMID: 20498493 Free PMC article.
-
Subject-specific analysis of joint contact mechanics: application to the study of osteoarthritis and surgical planning.J Biomech Eng. 2013 Feb;135(2):021003. doi: 10.1115/1.4023386. J Biomech Eng. 2013. PMID: 23445048 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical