Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Mar 13;115(10):1191-200.
doi: 10.1161/CIRCULATIONAHA.106.672162. Epub 2007 Feb 12.

Remote magnetic navigation to guide endocardial and epicardial catheter mapping of scar-related ventricular tachycardia

Affiliations

Remote magnetic navigation to guide endocardial and epicardial catheter mapping of scar-related ventricular tachycardia

Arash Aryana et al. Circulation. .

Abstract

Background: The present study examines the safety and feasibility of using a remote magnetic navigation system to perform endocardial and epicardial substrate-based mapping and radiofrequency ablation in patients with scar-related ventricular tachycardia (VT).

Methods and results: Using the magnetic navigation system, we performed 27 procedures on 24 consecutive patients with a history of VT related to myocardial infarction, dilated cardiomyopathy, arrhythmogenic right ventricular cardiomyopathy, hypertrophic cardiomyopathy, or sarcoidosis. Electroanatomic mapping of the left ventricular, right ventricular, and ventricular epicardial surfaces was constructed in 24, 10, and 12 patients, respectively. Complete-chamber VT activation maps were created in 4 patients. A total of 77 VTs were inducible, of which 21 were targeted during VT with the remotely navigated radiofrequency ablation catheter alone. With a combination of entrainment and activation mapping, 17 of 21 VTs (81%) were successfully terminated in a mean of 8.4+/-8.2 seconds; for the remainder, irrigated radiofrequency ablation was necessary. The mean fluoroscopy times for endocardial and epicardial mapping were 27+/-23 seconds (range, 0 to 105 seconds) and 18+/-18 seconds (range, 0 to 49 seconds), respectively. In concert with a manually navigated irrigated ablation catheter, 75 of 77 VTs (97%) were ultimately ablated. Four patients underwent a second procedure for recurrent VT, 3 with the magnetic navigation system. After 1.2 procedures per patient, VT did not recur during a mean follow-up of 7+/-3 months (range, 2 to 12 months).

Conclusions: The present study demonstrates the safety and feasibility of remote catheter navigation to perform substrate mapping of scar-related VT in a wide range of disease states with a minimal amount of fluoroscopy exposure.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources