Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007;26(4):570-577.
doi: 10.1002/nau.20374.

Bladder inhibition or voiding induced by pudendal nerve stimulation in chronic spinal cord injured cats

Affiliations

Bladder inhibition or voiding induced by pudendal nerve stimulation in chronic spinal cord injured cats

Changfeng Tai et al. Neurourol Urodyn. 2007.

Abstract

Aims: To investigate pudendal-to-bladder spinal reflexes in chronic spinal cord injured (SCI) cats induced by electrical stimulation of the pudendal nerve.

Methods: Bladder inhibition or voiding induced by pudendal nerve stimulation at different frequencies (3 or 20 Hz) was studied in three female, chronic SCI cats under alpha-chloralose anesthesia.

Results: Voiding induced by a slow infusion (2-4 ml/min) of saline into the bladder was very inefficient (voiding efficiency=7.3%+/-0.9%). Pudendal nerve stimulation at 3 Hz applied during the slow infusion inhibited reflex bladder activity, and significantly increased bladder capacity to 147.2+/-6.1% of its control capacity. When the 3-Hz stimulation was terminated, voiding rapidly occurred and the voiding efficiency was increased to 25.4+/-6.1%, but residual bladder volume was not reduced. Pudendal nerve stimulation at 20 Hz induced large bladder contractions, but failed to induce voiding during the stimulation due to the direct activation of the motor pathway to the external urethral sphincter. However, intermittent pudendal nerve stimulation at 20 Hz induced post-stimulus voiding with 78.3+/-12.1% voiding efficiency. The voiding pressures (39.3+/-6.2 cmH2O) induced by the intermittent pudendal nerve stimulation were higher than the voiding pressures (23.1+/-1.7 cmH2O) induced by bladder distension. The flow rate during post-stimulus voiding induced by the intermittent pudendal nerve stimulation was significantly higher (0.93+/-0.04 ml/sec) than during voiding induced by bladder distension (0.23+/-0.07 ml/sec).

Conclusions: This study indicates that a neural prosthetic device based on pudendal nerve stimulation might be developed to restore micturition function for people with SCI.

PubMed Disclaimer

Publication types

LinkOut - more resources