Robust 3-D modeling of vasculature imagery using superellipsoids
- PMID: 17304736
- DOI: 10.1109/TMI.2006.889722
Robust 3-D modeling of vasculature imagery using superellipsoids
Abstract
This paper presents methods to model complex vasculature in three-dimensional (3-D) images using cylindroidal superellipsoids, along with robust estimation and detection algorithms for automated image analysis. This model offers an explicit, low-order parameterization, enabling joint estimation of boundary, centerlines, and local pose. It provides a geometric framework for directed vessel traversal, and extraction of topological information like branch point locations and connectivity. M-estimators provide robust region-based statistics that are used to drive the superellipsoid toward a vessel boundary. A robust likelihood ratio test is used to differentiate between noise, artifacts, and other complex unmodeled structures, thereby verifying the model estimate. The proposed methodology behaves well across scale-space, shows a high degree of insensitivity to adjacent structures and implicitly handles branching. When evaluated on synthetic imagery mimicking specific structural complexities in tumor microvasculature, it consistently produces ubvoxel accuracy estimates of centerlines and widths in the presence of closely-adjacent vessels, branch points, and noise. An edit-based validation demonstrated a precision level of 96.6% at a recall level of 95.4%. Overall, it is robust enough for large-scale application.
Similar articles
-
Analysis of retinal vasculature using a multiresolution Hermite model.IEEE Trans Med Imaging. 2007 Feb;26(2):137-52. doi: 10.1109/TMI.2006.889732. IEEE Trans Med Imaging. 2007. PMID: 17304729
-
Unified anomaly suppression and boundary extraction in laser radar range imagery based on a joint curve-evolution and expectation-maximization algorithm.IEEE Trans Image Process. 2008 May;17(5):757-66. doi: 10.1109/TIP.2008.919363. IEEE Trans Image Process. 2008. PMID: 18390380
-
High-accuracy and robust localization of large control markers for geometric camera calibration.IEEE Trans Pattern Anal Mach Intell. 2009 Feb;31(2):376-83. doi: 10.1109/TPAMI.2008.214. IEEE Trans Pattern Anal Mach Intell. 2009. PMID: 19110502
-
Statistical shape models for 3D medical image segmentation: a review.Med Image Anal. 2009 Aug;13(4):543-63. doi: 10.1016/j.media.2009.05.004. Epub 2009 May 27. Med Image Anal. 2009. PMID: 19525140 Review.
-
Fractal and multifractal analysis: a review.Med Image Anal. 2009 Aug;13(4):634-49. doi: 10.1016/j.media.2009.05.003. Epub 2009 May 27. Med Image Anal. 2009. PMID: 19535282 Review.
Cited by
-
Automated 5-D analysis of cell migration and interaction in the thymic cortex from time-lapse sequences of 3-D multi-channel multi-photon images.J Immunol Methods. 2009 Jan 1;340(1):65-80. doi: 10.1016/j.jim.2008.09.024. Epub 2008 Nov 4. J Immunol Methods. 2009. PMID: 18992251 Free PMC article.
-
A nanoparticle size series for in vivo fluorescence imaging.Angew Chem Int Ed Engl. 2010 Nov 8;49(46):8649-52. doi: 10.1002/anie.201003142. Angew Chem Int Ed Engl. 2010. PMID: 20886481 Free PMC article. No abstract available.
-
Three-dimensional microscopy of the tumor microenvironment in vivo using optical frequency domain imaging.Nat Med. 2009 Oct;15(10):1219-23. doi: 10.1038/nm.1971. Epub 2009 Sep 13. Nat Med. 2009. PMID: 19749772 Free PMC article.
-
Automated three-dimensional choroidal vessel segmentation of 3D 1060 nm OCT retinal data.Biomed Opt Express. 2013 Jan 1;4(1):134-50. doi: 10.1364/BOE.4.000134. Epub 2012 Dec 17. Biomed Opt Express. 2013. PMID: 23304653 Free PMC article.
-
MDL constrained 3-D grayscale skeletonization algorithm for automated extraction of dendrites and spines from fluorescence confocal images.Neuroinformatics. 2009 Dec;7(4):213-32. doi: 10.1007/s12021-009-9057-y. Epub 2009 Dec 11. Neuroinformatics. 2009. PMID: 20012509 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources