Development of a nonintrusive blood pressure estimation system for computer users
- PMID: 17309356
- DOI: 10.1089/tmj.2006.0034
Development of a nonintrusive blood pressure estimation system for computer users
Abstract
An individual's cardiovascular health is important. The measurement of blood pressure (BP) can be performed nonintrusively during normal daily activities. A study was designed to estimate systolic BP by measuring pulse arrival time (PAT) nonintrusively. PAT was obtained nonintrusively to estimate each individual's BP while he or she worked at a computer. Electrocardiogram (ECG) was measured with a capacitive-coupled electrocardiogram (CC-ECG) system and photoplethysmogram (PPG) was measured using specially installed circuits in a computer mouse. PAT was calculated from CC-ECG and PPG, and compared to PAT measured by the standard method. Three individuals participated in this study. Results correlated well. An equation to estimate BP from the measured PAT was derived for each of three individuals during a training period. Estimated BP was compared with measured BP in a series of experiments under varied BP conditions. For each individual, the estimated BP followed the measured BP within a tolerable error range. This method was also used for long-term BP monitoring. Results showed that this method could be useful for monitoring BP for telemedicine and e-health.
Similar articles
-
A new approach for non-intrusive monitoring of blood pressure on a toilet seat.Physiol Meas. 2006 Feb;27(2):203-11. doi: 10.1088/0967-3334/27/2/010. Epub 2006 Jan 6. Physiol Meas. 2006. PMID: 16400206
-
Enhancing the estimation of blood pressure using pulse arrival time and two confounding factors.Physiol Meas. 2010 Feb;31(2):145-57. doi: 10.1088/0967-3334/31/2/002. Epub 2009 Dec 11. Physiol Meas. 2010. PMID: 20009186
-
Characters available in photoplethysmogram for blood pressure estimation: beyond the pulse transit time.Australas Phys Eng Sci Med. 2014 Jun;37(2):367-76. doi: 10.1007/s13246-014-0269-6. Epub 2014 Apr 11. Australas Phys Eng Sci Med. 2014. PMID: 24722801
-
Nonintrusive measurement of biological signals for ubiquitous healthcare.Annu Int Conf IEEE Eng Med Biol Soc. 2009;2009:6573-5. doi: 10.1109/IEMBS.2009.5334000. Annu Int Conf IEEE Eng Med Biol Soc. 2009. PMID: 19964697 Review.
-
A Literature Review on Current and Proposed Technologies of Noninvasive Blood Pressure Measurement.Telemed J E Health. 2018 Mar;24(3):185-193. doi: 10.1089/tmj.2017.0068. Epub 2017 Aug 7. Telemed J E Health. 2018. PMID: 28783442 Review.
Cited by
-
Flexible capacitive electrodes for minimizing motion artifacts in ambulatory electrocardiograms.Sensors (Basel). 2014 Aug 12;14(8):14732-43. doi: 10.3390/s140814732. Sensors (Basel). 2014. PMID: 25120162 Free PMC article.
-
Application of Handheld Tele-ECG for Health Care Delivery in Rural India.Int J Telemed Appl. 2014;2014:981806. doi: 10.1155/2014/981806. Epub 2014 Sep 28. Int J Telemed Appl. 2014. PMID: 25368654 Free PMC article.
-
Novel Digital Technologies for Blood Pressure Monitoring and Hypertension Management.Curr Cardiovasc Risk Rep. 2021;15(8):11. doi: 10.1007/s12170-021-00672-w. Epub 2021 Jun 9. Curr Cardiovasc Risk Rep. 2021. PMID: 34127936 Free PMC article. Review.
-
Calibration-Free Cuffless Blood Pressure Estimation Based on a Population With a Diverse Range of Age and Blood Pressure.Front Med Technol. 2021 Jul 27;3:695356. doi: 10.3389/fmedt.2021.695356. eCollection 2021. Front Med Technol. 2021. PMID: 35047937 Free PMC article.
-
Continuous Blood Pressure Monitoring as a Basis for Ambient Assisted Living (AAL) - Review of Methodologies and Devices.J Med Syst. 2019 Jan 2;43(2):24. doi: 10.1007/s10916-018-1138-8. J Med Syst. 2019. PMID: 30603777 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources