Normal MRI appearance and motion-related phenomena of CSF
- PMID: 17312059
- DOI: 10.2214/AJR.05.0003
Normal MRI appearance and motion-related phenomena of CSF
Abstract
Objective: The purpose of this article is to review the normal appearance of CSF, flow physics in relation to CSF flow dynamics, and commonly encountered appearances and artifacts of CSF due to superimposed flow effects.
Conclusion: Normal CSF has inherent MRI properties of low signal intensity on T1-weighted sequences and high signal intensity on T2-weighted sequences. However, the normal CSF signal is frequently altered by superimposed flow phenomena that can confound interpretation.
Similar articles
-
Relationship between contrast enhancement on fluid-attenuated inversion recovery MR sequences and signal intensity on T2-weighted MR images: visual evaluation of brain tumors.J Magn Reson Imaging. 2005 Jun;21(6):694-700. doi: 10.1002/jmri.20331. J Magn Reson Imaging. 2005. PMID: 15906343
-
Driven equilibrium (drive) MR imaging of the cranial nerves V-VIII: comparison with the T2-weighted 3D TSE sequence.Eur J Radiol. 2004 Sep;51(3):234-40. doi: 10.1016/j.ejrad.2003.10.019. Eur J Radiol. 2004. PMID: 15294330
-
Origin and reduction of motion and f0 artifacts in high resolution T2*-weighted magnetic resonance imaging: application in Alzheimer's disease patients.Neuroimage. 2010 Jul 1;51(3):1082-8. doi: 10.1016/j.neuroimage.2010.03.048. Epub 2010 Mar 22. Neuroimage. 2010. PMID: 20338252
-
MR imaging artifacts. Challenges and solutions.Magn Reson Imaging Clin N Am. 1999 Nov;7(4):717-32. Magn Reson Imaging Clin N Am. 1999. PMID: 10631675 Review.
-
Motion artifacts in brain and spine MR.Radiol Clin North Am. 1988 Jul;26(4):737-53. Radiol Clin North Am. 1988. PMID: 3289073 Review.
Cited by
-
Intracranial cerebrospinal fluid spaces imaging using a pulse-triggered three-dimensional turbo spin echo MR sequence with variable flip-angle distribution.Eur Radiol. 2011 Feb;21(2):402-10. doi: 10.1007/s00330-010-1925-1. Epub 2010 Aug 21. Eur Radiol. 2011. PMID: 20725835
-
Reliability of CT myelography versus MRI in the assessment of spinal epidural disease.Clin Imaging. 2020 Jun;62:37-40. doi: 10.1016/j.clinimag.2020.01.023. Epub 2020 Feb 1. Clin Imaging. 2020. PMID: 32044578 Free PMC article. No abstract available.
-
Respiratory brain impulse propagation in focal epilepsy.Sci Rep. 2023 Mar 30;13(1):5222. doi: 10.1038/s41598-023-32271-7. Sci Rep. 2023. PMID: 36997658 Free PMC article.
-
Elevated Surfactant Protein Levels and Increased Flow of Cerebrospinal Fluid in Cranial Magnetic Resonance Imaging.Mol Neurobiol. 2018 Aug;55(8):6227-6236. doi: 10.1007/s12035-017-0835-5. Epub 2017 Dec 27. Mol Neurobiol. 2018. PMID: 29282698
-
"Flow Void Sign": Flow Artifact on T2-Weighted MRI Can Be an Indicator of Dural Defect Location in Ventral Type 1 Spinal CSF Leaks.AJNR Am J Neuroradiol. 2025 Jan 8;46(1):211-218. doi: 10.3174/ajnr.A8445. AJNR Am J Neuroradiol. 2025. PMID: 39134372
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical