Abstract
The diffusion of minimally invasive cardiac surgery (MICS) during open-heart surgery has increased the use of assisted venous drainage support for cardiopulmonary bypass (CPB). Peripheral cannulation with small cannulae and vacuum-assisted venous drainage (VAVD) during MICS has been adopted in our institution since 1998. After the Heartport technique (HP) experience, the trans-thoracic clamp technique is now currently used. The aim of this study is to report our experience with extrathoracic CPB with VAVD application (on CPB) during open-heart MICS. From October 1999 to June 2006, 193 patients underwent MICS. Thirty-seven (19.2%) patients were treated with the HP--13 (35%) with robotic technology and 156 (80.8%) with trans-thoracic aortic clamping (TTAC). Mean age was 39 years (range: 12-77), and 114 patients (59.1%) were female. A total of 128 patients (66.3%) underwent mitral valve surgery, 57 (29.6%) atrial septal defect closure, five (2.6%) cardiac mass removal, and three (1.5%) tricuspid valve repair. Four patients (2.0%) had a previous cardiac procedure. Peripheral CPB was established with a standard coated circuit. A 14 Fr arterial cannula was inserted into the right jugular vein and positioned at the atrial/superior vena cava junction. A 21 or 28 percutaneous femoral cannula, depending on body surface area, was inserted in the femoral vein and an arterial cannula in the right femoral artery. Gravitational drainage was combined with VAVD. To improve the safety and effectiveness of this technique, we monitored the pressure on each venous cannula and in the reservoir. The mean CPB time was 74.8 +/- 30 min (TTAC) and 119 +/- 48 min (HP); mean aortic clamping time was 51 +/- 19 min (TTAC) and 73 +/- 29 min (HP). We did not record any neurological complication. Two patients (1.0%), one from each group, were converted to sternotomy. Three patients (1.5%) underwent re-exploration for bleeding. In-hospital mortality was 0.5% (N = 1) (HP). Mechanical ventilation time and intensive care unit stay were comparable to those recorded with conventional sternotomy. In conclusion, we found that extrathoracic CPB and VAVD during trans-thoracic clamping is a safe, simple, and effective technique for MICS. However, there is a potential risk of haemolysis and air embolism, which can be prevented with vacuum monitoring, and with the addition of gravitational drainage to reduce vacuum pressure.
Similar articles
-
Vacuum-assisted venous drainage and gaseous microemboli in cardiopulmonary bypass.J Extra Corpor Technol. 2008 Dec;40(4):249-56. J Extra Corpor Technol. 2008. PMID: 19192754 Free PMC article. Review.
-
A New Venous Drainage Technique in Minimally Invasive Redo Tricuspid Surgery: Vacuum-Assist Venous Drainage via a Single Femoral Venous Cannula.Heart Lung Circ. 2017 Feb;26(2):201-204. doi: 10.1016/j.hlc.2016.06.1219. Epub 2016 Aug 17. Heart Lung Circ. 2017. PMID: 27601288
-
Single Femoral Venous Drainage Versus Both Vena Cava Drainage in Isolated Repeat Tricuspid Valve Surgery.Int Heart J. 2018 May 30;59(3):518-522. doi: 10.1536/ihj.17-169. Epub 2018 May 20. Int Heart J. 2018. PMID: 29681570
-
Peripheral cardiopulmonary bypass with modified assisted venous drainage and transthoracic aortic crossclamp: optimal management for robotic mitral valve repair.Perfusion. 2003 Sep;18(5):307-11. doi: 10.1191/0267659103pf682oa. Perfusion. 2003. PMID: 14604249 Clinical Trial.
-
Single, percutaneous, femoral venous cannulation for cardiopulmonary bypass.Perfusion. 2007 May;22(3):211-5. doi: 10.1177/0267659107083021. Perfusion. 2007. PMID: 18018402 Review.
Cited by
-
Vacuum-Assisted Venous Drainage: A 2014 Safety Survey.J Extra Corpor Technol. 2015 Sep;47(3):160-6. J Extra Corpor Technol. 2015. PMID: 26543250 Free PMC article.
-
Optimizing venous drainage using an ultrasonic flow probe on the venous line.J Extra Corpor Technol. 2011 Sep;43(3):157-61. J Extra Corpor Technol. 2011. PMID: 22164455 Free PMC article.
-
2024 EACTS/EACTAIC/EBCP Guidelines on cardiopulmonary bypass in adult cardiac surgery.Eur J Cardiothorac Surg. 2025 Feb 4;67(2):ezae354. doi: 10.1093/ejcts/ezae354. Eur J Cardiothorac Surg. 2025. PMID: 39949326 Free PMC article. No abstract available.
-
Vacuum-assisted venous drainage and gaseous microemboli in cardiopulmonary bypass.J Extra Corpor Technol. 2008 Dec;40(4):249-56. J Extra Corpor Technol. 2008. PMID: 19192754 Free PMC article. Review.
-
The effect of vacuum-assisted venous drainage on hemolysis during cardiopulmonary bypass.Am J Cardiovasc Dis. 2020 Oct 15;10(4):473-478. eCollection 2020. Am J Cardiovasc Dis. 2020. PMID: 33224598 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous