Comparison between thallium-201 and technetium-99m methoxyisobutyl isonitrile defect size in single-photon emission computed tomography at rest, exercise and redistribution in coronary artery disease
- PMID: 1731457
- DOI: 10.1016/0002-9149(92)91302-k
Comparison between thallium-201 and technetium-99m methoxyisobutyl isonitrile defect size in single-photon emission computed tomography at rest, exercise and redistribution in coronary artery disease
Abstract
Defect size on myocardial tomograms was measured in 30 patients who underwent 2 separate studies, 1 with thallium-201 (TI-201), the other with technetium-99m-methoxyisobutyl isonitrile (MIBI). A group of 15 patients with myocardial infarction was studied at rest and received both tracers on the same day. The other 15 patients had documented coronary artery disease. They were were given injections of TI-201 at peak exercise and underwent imaging immediately after exercise and again 4 hours later. They then received a dose of MIBI for imaging at rest. A week later they underwent a second exercise test with the same work load and received a second dose of MIBI. Defect size on single-photon emission computed tomographic images was measured and repeated twice. Results were expressed in percentage of the volume of the whole myocardium. Reproducibility of the defect size measurement was high for TI-201 (r = 0.978; SEE = 1.59) as well as for MIBI (r = 0.981; SEE = 0.80). In patients with coronary artery disease the mean size of the defects was significantly larger with TI-201 than with MIBI at exercise (6.7 +/- 5.2 vs 4.6 +/- 5.2%, respectively, p less than 0.05) and at redistribution (5.1 +/- 4.4 vs 2.8 +/- 3.2%, respectively, p less than 0.05), where no difference was seen in patients with myocardial infarction studied only at rest (11.2 +/- 10.4 vs 12.0 +/- 11.5%, respectively, p = not significant). Smaller MIBI defect sizes, when compared with TI-201, in the exercise and redistribution studies were not due to technical artefacts since there was no difference when they were compared at rest.
Similar articles
-
Comparison of thallium-201 and technetium-99m hexakis 2-methoxyisobutyl isonitrile single-photon emission computed tomography for estimating the extent of myocardial ischemia and infarction in coronary artery disease.Am J Cardiol. 1990 Dec 15;66(20):1438-44. doi: 10.1016/0002-9149(90)90530-e. Am J Cardiol. 1990. PMID: 2147536 Clinical Trial.
-
[Myocardial scintigraphy with Tc-99m-MIBI for assessing the extent and severity of coronary disease: a comparison with thallium-201 and equilibrium angiocardioscintigraphy].G Ital Cardiol. 1993 Feb;23(2):127-38. G Ital Cardiol. 1993. PMID: 8491353 Italian.
-
Comparison of technetium 99m methoxy isobutyl isonitrile and thallium 201 for evaluation of coronary artery disease by planar and tomographic methods.Am Heart J. 1989 Jan;117(1):1-11. doi: 10.1016/0002-8703(89)90649-2. Am Heart J. 1989. PMID: 2643279
-
The new 99mTc myocardial perfusion imaging agents: 99mTc-sestamibi and 99mTc-teboroxime.Circulation. 1991 Sep;84(3 Suppl):I7-21. Circulation. 1991. PMID: 1832100 Review.
-
Myocardial perfusion imaging with technetium-99m sestamibi SPECT in the evaluation of coronary artery disease.Am J Cardiol. 1990 Oct 16;66(13):55E-62E. doi: 10.1016/0002-9149(90)90613-6. Am J Cardiol. 1990. PMID: 2145748 Review.
Cited by
-
Technetium 99m furifosmin regional myocardial uptake in patients with previous myocardial infarction: relation to thallium-201 activity and left ventricular function.J Nucl Cardiol. 2000 May-Jun;7(3):235-41. doi: 10.1016/s1071-3581(00)70012-2. J Nucl Cardiol. 2000. PMID: 10888394
-
Simultaneous dual-isotope technetium-99m/thallium-201 cardiac SPET imaging using a projection-dependent spilldown correction factor.Eur J Nucl Med. 1995 May;22(5):465-72. doi: 10.1007/BF00839061. Eur J Nucl Med. 1995. PMID: 7641755
-
Return of dual-isotope SPECT myocardial perfusion imaging? Not so fast….J Nucl Cardiol. 2015 Jun;22(3):523-5. doi: 10.1007/s12350-014-0034-y. J Nucl Cardiol. 2015. PMID: 25423933 No abstract available.
-
Diagnostic value of stress thallium-201/rest technetium-99m-sestamibi sequential dual isotope high-speed myocardial perfusion imaging for the detection of haemodynamically relevant coronary artery stenosis.J Nucl Cardiol. 2019 Aug;26(4):1269-1279. doi: 10.1007/s12350-018-1189-8. Epub 2018 Jan 29. J Nucl Cardiol. 2019. PMID: 29380286
-
One-year prognosis of patients with normal planar or single-photon emission computed tomographic technetium 99m-labeled sestamibi exercise imaging.J Nucl Cardiol. 1994 Sep-Oct;1(5 Pt 1):449-56. doi: 10.1007/BF02961599. J Nucl Cardiol. 1994. PMID: 9420729
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources