Side-view analysis of the lens. I. The crystalline lens and the evacuated bag
- PMID: 1731729
- DOI: 10.1001/archopht.1992.01080130091032
Side-view analysis of the lens. I. The crystalline lens and the evacuated bag
Abstract
A new technique for studying the anatomy of the lens and other anterior chamber structures in human eyes obtained post mortem is described. An oblique or side view is achieved by creating a uveoscleral window. This provides a clear three-dimensional view of such structures as the crystalline lens, zonular apparatus, and ciliary body. The crystalline lens is shown to be approximately 4.5 mm thick and 9.5 mm in diameter. The equator of the lens is 0.2 to 0.3 mm from the center of the ciliary body. After removal of lens substance, the capsular bag collapses, its thickness approaches zero, and the total diameter increases to 10.5 mm. Filling of the capsular bag with a viscoelastic material restores the configuration of the lens to its original state. This technique is also useful for demonstrating the dynamics of surgical procedures during cataract operation.
Similar articles
-
Relationship between lens and capsular bag size.J Cataract Refract Surg. 1998 Apr;24(4):547-51. doi: 10.1016/s0886-3350(98)80300-3. J Cataract Refract Surg. 1998. PMID: 9584254
-
The suspensory apparatus of the canine lens.J Anat. 1983 Jan;136(Pt 1):69-83. J Anat. 1983. PMID: 6833122 Free PMC article.
-
Side-view analysis of the lens. II. Positioning of intraocular lenses.Arch Ophthalmol. 1992 Jan;110(1):94-7. doi: 10.1001/archopht.1992.01080130096034. Arch Ophthalmol. 1992. PMID: 1731730
-
The lens capsule and zonulae.Acta Ophthalmol Suppl (1985). 1992;(205):7-12. doi: 10.1111/j.1755-3768.1992.tb02175.x. Acta Ophthalmol Suppl (1985). 1992. PMID: 1332416 Review.
-
Techniques of intraocular lens suspension in the absence of capsular/zonular support.Surv Ophthalmol. 2005 Sep-Oct;50(5):429-62. doi: 10.1016/j.survophthal.2005.06.010. Surv Ophthalmol. 2005. PMID: 16139038 Review.
Cited by
-
Lenticular Imaging: A New Experimental and Quantitative Analysis of Capsular Dynamics, "Choi-Apple View".Transl Vis Sci Technol. 2019 May 20;8(3):22. doi: 10.1167/tvst.8.3.22. eCollection 2019 May. Transl Vis Sci Technol. 2019. PMID: 31149393 Free PMC article.
-
Optical principles, biomechanics, and initial clinical performance of a dual-optic accommodating intraocular lens (an American Ophthalmological Society thesis).Trans Am Ophthalmol Soc. 2006;104:437-52. Trans Am Ophthalmol Soc. 2006. PMID: 17471355 Free PMC article. Clinical Trial.
-
Species Differences in the Geometry of the Anterior Segment Differentially Affect Anterior Chamber Cell Scoring Systems in Laboratory Animals.J Ocul Pharmacol Ther. 2016 Jan-Feb;32(1):28-37. doi: 10.1089/jop.2015.0071. Epub 2015 Nov 5. J Ocul Pharmacol Ther. 2016. PMID: 26539819 Free PMC article.
-
Influence of total intraocular lens diameter on efficacy and safety for in the bag cataract surgery.Oman J Ophthalmol. 2018 May-Aug;11(2):144-149. doi: 10.4103/ojo.OJO_143_2017. Oman J Ophthalmol. 2018. PMID: 29930449 Free PMC article.
-
Retinal detachment following cataract surgery with capsulorhexis.Trans Am Ophthalmol Soc. 1995;93:391-7; discussion 397-401. Trans Am Ophthalmol Soc. 1995. PMID: 8719688 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources