Modified incision in 25-gauge vitrectomy in the creation of a tunneled airtight sclerotomy: an ultrabiomicroscopic study
- PMID: 17318571
- DOI: 10.1007/s00417-006-0533-x
Modified incision in 25-gauge vitrectomy in the creation of a tunneled airtight sclerotomy: an ultrabiomicroscopic study
Abstract
Background: The standard straight incision for 25-gauge vitrectomy may not close well at the end of surgery with post-operative hypotony. To overcome incompetent wound closure, oblique insertion of the trocars has been suggested. More recently we have developed an oblique incision. which is parallel to the scleral fibres instead of perpendicular and therefore avoids cutting. The aim of this study was to compare the effectiveness of the different incisions and to investigate their behaviour with the UBM.
Methods: 45 patients affected by macular holes were operated; in 15 eyes using oblique-parallel insertion (OPAI), in 15 oblique-perpendicular (OPEI) and in 15 straight incision (SI). Patients underwent UBM examinations 1 day, 1 week, 1 month p.o.
Results: OPAI was airtight after the removal of 25 g cannulas. UBM examination 1 day post-operatively (p.o) showed the 45 sclerotomies were well healed with perfect apposition of the internal wound lips. 39 sclerotomies were undetectable, 6 slightly evident. With OPEI the incisions were airtight at the end of surgery. At the 1 day p.o. UBM examination the 45 sclerotomies were well-healed but a minimal gape was clearly visible in all of them, 3 eyes showed peripheral cilio-choroidal (CCD) detachment, which was resolved after 7 days although the gape was still evident. At 1 month p.o. examination the gape was not detectable in 20 sites, evident in 25. With SI at the end of the surgery conjunctival bleb formation was detected in 10 cases, air-gas refilling was performed in 7 eyes and 3 sclerotomies were sutured. At 1 day p.o. hypotony was recorded in 5 patients, recovering at the 7 day follow-up. At the 1 day p.o. UBM examination showed a significant gape in all sites, weak vitreous entrapment was shown in 36, subconjunctival fluid in 4, CCD in 7. At the 7 day UBM the CCD had disappeared in 4 and was reduced in 3. At the 1 month p.o. the sclerotomy defect was still detectable but other complications were no longer evident.
Conclusions: OPAI achieved the quickest and most complete sealing since the 1st day p.o without complications, therefore it could be safer when performing 25-g vitrectomy with extensive manipulation.
Similar articles
-
Ultrasound biomicroscopy study of direct and oblique 25-gauge vitrectomy sclerotomies.Am J Ophthalmol. 2007 May;143(5):881-3. doi: 10.1016/j.ajo.2006.12.036. Am J Ophthalmol. 2007. PMID: 17452179
-
Ultrasound biomicroscopy imaging of sclerotomy in children with cataract undergoing 25-gauge sutureless pars plana anterior vitrectomy.Eur J Ophthalmol. 2010 Nov-Dec;20(6):1053-8. doi: 10.1177/112067211002000605. Eur J Ophthalmol. 2010. PMID: 20491045
-
Ultrasound biomicroscopic findings of conventional and sutureless sclerotomy sites after 20-, 23-, and 25-G pars plana vitrectomy.Eye (Lond). 2010 Jul;24(7):1268-72. doi: 10.1038/eye.2009.291. Epub 2009 Dec 11. Eye (Lond). 2010. PMID: 20010792
-
Influence of the source of incisional vitreous incarceration on sclerotomy closure competency after transconjunctival sutureless vitrectomy.Curr Eye Res. 2014 Dec;39(12):1194-9. doi: 10.3109/02713683.2014.905609. Epub 2014 Apr 21. Curr Eye Res. 2014. PMID: 24749625
-
Ultrasound biomicroscopy in recently postoperative 23-gauge transconjunctival vitrectomy sutureless self-sealing sclerotomy.Retina. 2009 Oct;29(9):1305-9. doi: 10.1097/IAE.0b013e3181b09487. Retina. 2009. PMID: 19696703 Clinical Trial.
Cited by
-
Evaluation of mechanical closure resistance of sutureless vitrectomy sclerotomies after conjunctival cauterization with bipolar diathermy forceps.Graefes Arch Clin Exp Ophthalmol. 2016 Mar;254(3):489-95. doi: 10.1007/s00417-015-3243-4. Epub 2015 Dec 15. Graefes Arch Clin Exp Ophthalmol. 2016. PMID: 26666232
-
Influence of silicone oil tamponade on self-sealing sclerotomy using 25-gauge transconjunctival sutureless vitrectomy: a retrospective comparative study.BMC Ophthalmol. 2015 Dec 1;15:171. doi: 10.1186/s12886-015-0159-z. BMC Ophthalmol. 2015. PMID: 26626403 Free PMC article.
-
Occult globe perforation during posterior sub-tenon injection diagnosed by ultrasound biomicroscopy.Oman J Ophthalmol. 2022 Jun 29;15(2):231-233. doi: 10.4103/ojo.ojo_190_21. eCollection 2022 May-Aug. Oman J Ophthalmol. 2022. PMID: 35937720 Free PMC article.
-
Vitrectomy in high myopia: a narrative review.Int J Retina Vitreous. 2017 Oct 2;3:37. doi: 10.1186/s40942-017-0090-y. eCollection 2017. Int J Retina Vitreous. 2017. PMID: 29021916 Free PMC article. Review.
-
27-gauge and 25-gauge vitrectomy day surgery for idiopathic epiretinal membrane.BMC Ophthalmol. 2017 Oct 10;17(1):188. doi: 10.1186/s12886-017-0585-1. BMC Ophthalmol. 2017. PMID: 29017460 Free PMC article.