Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2007 Mar;65(3):424-9.
doi: 10.1016/j.gie.2006.08.027.

Use of a variable-stiffness colonoscope decreases the dose of patient-controlled sedation during colonoscopy: a randomized comparison of 3 colonoscopes

Affiliations
Randomized Controlled Trial

Use of a variable-stiffness colonoscope decreases the dose of patient-controlled sedation during colonoscopy: a randomized comparison of 3 colonoscopes

Danny W H Lee et al. Gastrointest Endosc. 2007 Mar.

Abstract

Background: The variable-stiffness colonoscope incorporates different degrees of stiffness of the insertion tube, which can be adjusted during the examination. Whether its use can lead to reduced procedure-related pain and sedative use is unknown.

Objective: Our purpose was to compare the use of 3 types of colonoscope with different shaft stiffnesses in relation to procedure-related pain and sedative consumption.

Design: Prospective randomized trial.

Setting: Endoscopy unit of a university-affiliated hospital.

Patients: Consecutive patients undergoing ambulatory colonoscopy.

Interventions: Random assignment was made of patients into 3 groups to receive colonoscopic examinations by one of the 3 types of colonoscope: conventional standard adult size, 1.3-m; 1.6-m; and the new variable-stiffness adult size, full-length (1.6-m) colonoscope. A mixture of propofol and afentanil, delivered by a patient-controlled syringe pump, was used for sedation in all groups.

Main outcome measures: Outcome measures included dose of patient-controlled sedation consumed, pain score, cecal intubation rate, cecal intubation time, requirement of abdominal pressure and change of patients' positions during colonoscopy, and endoscopists and patients' satisfaction scores according to a visual analog scale.

Results: A total of 335 patients were randomized. Patients in group 3 used significantly less propofol (in milligrams per kilograms, mean [SD]) compared with the other 2 groups (group 1: 1.00 [0.75], group 2: 0.93 [0.62], and group 3: 0.75 [0.65]; P = .02; 1-way analysis of variance). The mean (SD) pain score was also lower in group 3.

Limitations: The endoscopists were not blinded.

Conclusion: The use of the new variable-stiffness adult-size colonoscope significantly reduced procedure-related pain and doses of sedative medications during colonoscopy.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

LinkOut - more resources