Contrast sensitivity after implantation of a spherical versus an aspherical intraocular lens in biaxial microincision cataract surgery
- PMID: 17321388
- DOI: 10.1016/j.jcrs.2006.10.066
Contrast sensitivity after implantation of a spherical versus an aspherical intraocular lens in biaxial microincision cataract surgery
Abstract
Purpose: To determine whether implantation of a microincision intraocular lens (IOL) with a modified anterior surface, designed to compensate for the positive spherical aberration of the cornea in eyes of cataract patients, results in improved pseudophakic quality of vision in pseudophakic eyes after biaxial microincision phacoemulsification.
Setting: Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.
Methods: In a nonrandomized parallel cohort investigation, the visual performance of 52 eyes of 52 patients unilaterally implanted with the aspherical Acri. Smart 36 A IOL (Acri.Tec) were compared with those of 25 eyes of 25 age-matched patients unilaterally implanted with the spherical Acri. Smart 46 S IOL (Acri.Tec). Eight weeks after surgery, the following parameters were assessed: uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), pupil size under various illumination conditions, high-contrast and low-contrast visual acuities, photopic and mesopic contrast sensitivities, capsulorhexis size, and wavefront aberration of the cornea and eye. The primary clinical endpoint of the comparison was defined as the area under the cycles per degree (cpd) curve of the contrast sensitivity profile.
Results: The aspherical IOL group and the spherical IOL group did not differ in baseline characteristics. The median age was 71 years and 68% were women in the aspherical group versus 69 years and 62% women in the spherical group. The preoperative median UCVA was 20/80 in both groups. The UCVA, BCVA, pupil size, and capsulorhexis size were not statistically different between the 2 groups. Furthermore, no clinically relevant or statistically significant between-group differences were observed in the primary clinical endpoint. The median postoperative low mesopic contrast sensitivity without glare was 73 cpd in the aspherical group and 84 cpd in the spherical group (P = .624); a similar tendency was observed under high mesopic conditions (median 80 cpd and 83 cpd, respectively) (P = 1.000). Implantation of both IOL types resulted in a negative spherical aberration Z(4)(0), which was significantly different between the 2 groups (median -0.09 mum aspherical and -0.29 microm aspherical at a pupil size of 4.5 mm) (P<.001).
Conclusions: No clinically relevant postoperative differences in contrast sensitivity were observed between the aspherical microincision IOL and the spherical equivalent model. The development of microincision IOLs, which fit through corneal incisions smaller than 2.0 mm and improve night-driving conditions (eg, reduction of glare), could optimize modern biaxial cataract surgery.
Similar articles
-
Intraindividual comparison of aspherical and spherical intraocular lenses of same material and platform.Ophthalmology. 2009 May;116(5):896-901. doi: 10.1016/j.ophtha.2008.11.022. Ophthalmology. 2009. PMID: 19410948 Clinical Trial.
-
Visual performance of aspherical and spherical intraocular lenses: intraindividual comparison of visual acuity, contrast sensitivity, and higher-order aberrations.J Cataract Refract Surg. 2006 Dec;32(12):2022-9. doi: 10.1016/j.jcrs.2006.07.029. J Cataract Refract Surg. 2006. PMID: 17137978 Clinical Trial.
-
Ocular aberrations and contrast sensitivity after cataract surgery with AcrySof IQ intraocular lens implantation Clinical comparative study.J Cataract Refract Surg. 2007 Nov;33(11):1918-24. doi: 10.1016/j.jcrs.2007.06.053. J Cataract Refract Surg. 2007. PMID: 17964398 Clinical Trial.
-
Advances in microincision cataract surgery intraocular lenses.Curr Opin Ophthalmol. 2006 Feb;17(1):80-93. doi: 10.1097/01.icu.0000192520.48411.fa. Curr Opin Ophthalmol. 2006. PMID: 16436929 Review.
-
Incision sizes before and after implantation of 6-mm optic foldable intraocular lenses using Monarch and Unfolder injector systems.Ophthalmology. 2005 Jan;112(1):58-66. doi: 10.1016/j.ophtha.2004.06.030. Ophthalmology. 2005. PMID: 15629821 Review.
Cited by
-
Aspheric versus Spherical Posterior Chamber Intraocular Lenses.J Ophthalmic Vis Res. 2010 Oct;5(4):217-22. J Ophthalmic Vis Res. 2010. PMID: 22737364 Free PMC article.
-
Correlation between contrast sensitivity and higher-order aberration based on pupil diameter after cataract surgery.Clin Ophthalmol. 2011;5:1701-7. doi: 10.2147/OPTH.S21819. Epub 2011 Dec 7. Clin Ophthalmol. 2011. PMID: 22205829 Free PMC article.
-
A comparative study on visual and optical performance of Akreos AO and Kontur AB IOLs after phacoemulsification cataract surgery.J Curr Ophthalmol. 2016 Mar 28;28(1):12-6. doi: 10.1016/j.joco.2016.02.001. eCollection 2016 Mar. J Curr Ophthalmol. 2016. PMID: 27239596 Free PMC article.
-
[Aspheric intraocular lenses].Ophthalmologe. 2008 Mar;105(3):234-40. doi: 10.1007/s00347-008-1718-y. Ophthalmologe. 2008. PMID: 18311568 Review. German.
-
Comparison of contrast sensitivity, depth of field and ocular wavefront aberrations in eyes with an IOL with zero versus positive spherical aberration.Graefes Arch Clin Exp Ophthalmol. 2009 Jul;247(7):965-73. doi: 10.1007/s00417-009-1038-1. Epub 2009 Mar 11. Graefes Arch Clin Exp Ophthalmol. 2009. PMID: 19277694