Patient-ventilator interaction and sleep in mechanically ventilated patients: pressure support versus proportional assist ventilation
- PMID: 17334259
- DOI: 10.1097/01.CCM.0000260055.64235.7C
Patient-ventilator interaction and sleep in mechanically ventilated patients: pressure support versus proportional assist ventilation
Abstract
Objectives: To understand the role of patient-ventilator asynchrony in the etiology of sleep disruption and determine whether optimizing patient-ventilator interactions by using proportional assist ventilation improves sleep.
Design: Randomized crossover clinical trial.
Setting: A tertiary university medical-surgical intensive care unit.
Patients: Thirteen patients during weaning from mechanical ventilation.
Interventions: Patients were randomized to receive pressure support ventilation or proportional assist ventilation on the first night and then crossed over to the alternative mode for the second night. Polysomnography and measurement of light, noise, esophageal pressure, airway pressure, and flow were performed from 10 pm to 8 am. Ventilator settings (pressure level during pressure support ventilation and resistive and elastic proportionality factors during proportional assist ventilation) were set to obtain a 50% reduction of the inspiratory work (pressure time product per minute) performed during a spontaneous breathing trial.
Measurements and main results: Arousals per hour of sleep time during pressure support ventilation were 16 (range 2-74) and 9 (range 1-41) during proportional assist ventilation (p = .02). Overall sleep quality was significantly improved on proportional assist ventilation (p < .05) due to the combined effect of fewer arousals per hour, fewer awakenings per hour (3.5 [0-24] vs. 5.5 [1-24]), and greater rapid eye movement (9% [0-31] vs. 4% [0-23]), and slow wave (3% [0-16] vs. 1% [0-10]) sleep. Tidal volume and minute ventilation were lower on proportional assist ventilation, allowing for a greater increase in Paco2 during the night. Patient-ventilator asynchronies per hour were lower with proportional assist ventilation than with pressure support ventilation (24 +/- 15 vs. 53 +/- 59; p = .02) and correlated with the number of arousals per hour (R = .65, p = .0001).
Conclusions: Patient ventilator discordance causes sleep disruption. Proportional assist ventilation seems more efficacious than pressure support ventilation in matching ventilatory requirements with ventilator assistance, therefore resulting in fewer patient-ventilator asynchronies and better quality of sleep.
Comment in
-
In search of the elusive sleep in critically ill and mechanically ventilated patients.Crit Care Med. 2007 Apr;35(4):1202-4. doi: 10.1097/01.CCM.0000259494.88323.90. Crit Care Med. 2007. PMID: 17413790 No abstract available.
Similar articles
-
Comparison of sleep quality with mechanical versus spontaneous ventilation during weaning of critically III tracheostomized patients.Crit Care Med. 2013 Jul;41(7):1637-44. doi: 10.1097/CCM.0b013e318287f569. Crit Care Med. 2013. PMID: 23507721 Clinical Trial.
-
[Comparison of patient-ventilator synchronization during pressure support ventilation versus amplified spontaneous pattern in postoperative patients].Rev Esp Anestesiol Reanim. 2000 Jun-Jul;47(6):235-44. Rev Esp Anestesiol Reanim. 2000. PMID: 10981439 Clinical Trial. Spanish.
-
Influence of pressure- and flow-triggered synchronous intermittent mandatory ventilation on inspiratory muscle work.Crit Care Med. 1994 Dec;22(12):1933-41. Crit Care Med. 1994. PMID: 7988129 Clinical Trial.
-
Mechanical ventilation: let us minimize sleep disturbances.Curr Opin Crit Care. 2007 Feb;13(1):20-6. doi: 10.1097/MCC.0b013e3280121adc. Curr Opin Crit Care. 2007. PMID: 17198045 Review.
-
Sleep and mechanical ventilation.Crit Care Clin. 2008 Jul;24(3):517-31, vi-vii. doi: 10.1016/j.ccc.2008.03.002. Crit Care Clin. 2008. PMID: 18538198 Review.
Cited by
-
Patient-Ventilator Dyssynchrony.Korean J Crit Care Med. 2017 Nov;32(4):307-322. doi: 10.4266/kjccm.2017.00535. Epub 2017 Nov 30. Korean J Crit Care Med. 2017. PMID: 31723652 Free PMC article. Review.
-
Neurally adjusted ventilatory assist preserves cerebral blood flow velocity in patients recovering from acute brain injury.J Clin Monit Comput. 2021 May;35(3):627-636. doi: 10.1007/s10877-020-00523-w. Epub 2020 May 9. J Clin Monit Comput. 2021. PMID: 32388653 Free PMC article.
-
Delirium Incidence and Risk Factors in Adult Critically Ill Patients in Saudi Arabia.J Emerg Trauma Shock. 2019 Jan-Mar;12(1):30-34. doi: 10.4103/JETS.JETS_91_18. J Emerg Trauma Shock. 2019. PMID: 31057281 Free PMC article.
-
Sedation in non-invasive ventilation: do we know what to do (and why)?Multidiscip Respir Med. 2014 Nov 4;9(1):56. doi: 10.1186/2049-6958-9-56. eCollection 2014. Multidiscip Respir Med. 2014. PMID: 25699177 Free PMC article. Review.
-
Sleep and critical illness: bridging the two pillars at the ATS 2016.J Thorac Dis. 2016 Jul;8(Suppl 7):S536-8. doi: 10.21037/jtd.2016.07.41. J Thorac Dis. 2016. PMID: 27606086 Free PMC article. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical