Diagnostic accuracy of coronary in-stent restenosis using 64-slice computed tomography: comparison with invasive coronary angiography
- PMID: 17336718
- DOI: 10.1016/j.jacc.2006.10.065
Diagnostic accuracy of coronary in-stent restenosis using 64-slice computed tomography: comparison with invasive coronary angiography
Abstract
Objectives: This study sought to evaluate the diagnostic accuracy of coronary binary in-stent restenosis (ISR) with angiography using 64-slice multislice computed tomography coronary angiography (CTCA) compared with invasive coronary angiography (ICA).
Background: A noninvasive detection of ISR would result in an easier and safer way to conduct patient follow-up.
Methods: We performed CTCA in 81 patients after stent implantation, and 125 stented lesions were scanned. Two sets of images were reconstructed with different types of convolution kernels. On CTCA, neointimal proliferation was visually evaluated according to luminal contrast attenuation inside the stent. Lesions were graded as follows: grade 1, none or slight neointimal proliferation; grade 2, neointimal proliferation with no significant stenosis (<50%); grade 3, neointimal proliferation with moderate stenosis (> or =50%); and grade 4, neointimal proliferation with severe stenosis (> or =75%). Grades 3 and 4 were considered binary ISR. The diagnostic accuracy of CTCA compared with ICA was evaluated.
Results: By ICA, 24 ISRs were diagnosed. Sensitivity, specificity, positive predictive value, and negative predictive value were 92%, 81%, 54%, and 98% for the overall population, whereas values were 91%, 93%, 77%, and 98% when excluding unassessable segments (15 segments, 12%). For assessable segments, CTCA correctly diagnosed 20 of the 22 ISRs detected by ICA. Six lesions without ISR were overestimated as ISR by CTCA. As the grade of neointimal proliferation by CTCA increases, the median value of percent diameter stenosis increased linearly.
Conclusions: Binary ISR can be excluded with high probability by CTCA, with a moderate rate of false-positive results.
Comment in
-
Integrating multidetector computed tomography into clinical practice: computed tomography scanning shows its metal.J Am Coll Cardiol. 2007 Mar 6;49(9):960-2. doi: 10.1016/j.jacc.2006.12.016. Epub 2007 Feb 20. J Am Coll Cardiol. 2007. PMID: 17336719 No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous
