Aseptic meningitis after embolization of cerebral aneurysms using hydrogel-coated coils: report of three cases
- PMID: 17353325
- PMCID: PMC7977831
Aseptic meningitis after embolization of cerebral aneurysms using hydrogel-coated coils: report of three cases
Abstract
We report the development of aseptic meningitis in 3 patients with aneurysms treated with hydrogel-coated coils. Patients presented with febrile meningeal syndromes during the 24 hours following the procedures and responded to corticosteroids. One of them developed delayed hydrocephalus that required treatment with a ventriculoperitoneal shunt. Aseptic meningitis is one of the important complications related to hydrogel-coated coils that should be recognized. More information based on the posttreatment surveillance after use of hydrogel-coated coils is required.
References
-
- Meyers PM, Lavine SD, Fitzsimmons BF, et al. Chemical meningitis after cerebral aneurysm treatment using two second-generation aneurysm coils: report of two cases. Neurosurgery 2004;55:1222. - PubMed
-
- Murayama Y, Tateshima S, Gonzalez NR, et al. Matrix and bioabsorbable polymeric coils accelerate healing of intracranial aneurysms: long-term experimental study. Stroke 2003;34:2031–37 - PubMed