Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2007 Feb;65(1):60-3.
doi: 10.1080/00016350601058051.

In vitro quantification of smooth surface caries with DIAGNOdent and the DIAGNOdent pen

Affiliations
Comparative Study

In vitro quantification of smooth surface caries with DIAGNOdent and the DIAGNOdent pen

Abdulaziz Aljehani et al. Acta Odontol Scand. 2007 Feb.

Abstract

Objective: A new generation of the laser fluorescence device, DIAGNOdent, for caries detection and quantification has been introduced recently. It is the DIAGNOdent pen. The aim of this study was to compare the validity and reliability of both laser-based devices, DIAGNOdent and the DIAGNOdent pen, in quantifying smooth surface caries.

Material and methods: The material comprised a sample of 52 premolar teeth extracted on orthodontic indication. The teeth were visually sound or had various stages of non-cavitated carious lesions on smooth surfaces. All teeth were photographed and measured with both DIAGNOdent and the DIAGNOdent pen by two examiners independently. The teeth were then sectioned into 300-microm slices and analysed under a microscope for verification of lesion depth. Histopathological analyses were performed by two observers to assess lesion depth, which was classified into five categories ranging from sound to dentinal caries. Reliability and validity of the two devices were evaluated in terms of intra-class coefficients and Spearman rank correlation coefficient, respectively. The relation between measurements performed by DIAGNOdent and the DIAGNOdent pen was analyzed using Pearson's correlation coefficient.

Results: Both DIAGNOdent and the DIAGNOdent pen had excellent intra-observer agreement and acceptable inter-observer agreement. The correlation with histology for DIAGNOdent and the DIAGNOdent pen ranged between 0.47 and 0.57, although the correlation between DIAGNOdent and the DIAGNOdent pen was high.

Conclusions: In this in vitro study, the new laser fluorescence device, the DIAGNOdent pen, showed similar reliability and validity at quantification of smooth surface caries compared to the conventional DIAGNOdent device. Agreement between DIAGNOdent and the DIAGNOdent pen was excellent.

PubMed Disclaimer

LinkOut - more resources