C-arm tracking and reconstruction without an external tracker
- PMID: 17354927
- DOI: 10.1007/11866565_61
C-arm tracking and reconstruction without an external tracker
Abstract
For quantitative C-arm fluoroscopy, we have developed a unified mathematical framework to tackle the issues of intra-operative calibration, pose estimation, correspondence and reconstruction, without the use of optical/electromagnetic trackers or precision-made fiducial fixtures. Our method uses randomly distributed unknown points in the imaging volume, either naturally present or induced by randomly sticking beads or other simple markers in the image pace. After these points are segmented, a high dimensional non-linear optimization computes all unknown parameters for calibration, C-arm pose, correspondence and reconstruction. Preliminary phantom experiments indicate an average C-arm tracking accuracy of 0.9 degrees and a 3D reconstruction error of 0.8 mm, with an 80 region of convergence for both the AP and lateral axes. The method appears to be sufficiently accurate for many clinical applications, and appealing since it works without any external instrumentation and does not interfere with the workspace.
Similar articles
-
CTREC: C-arm Tracking and Reconstruction using Elliptic Curves.Conf Comput Vis Pattern Recognit Workshops. 2008 Jun;2008:10.1109/CVPRW.2008.4563029. doi: 10.1109/CVPRW.2008.4563029. Conf Comput Vis Pattern Recognit Workshops. 2008. PMID: 26257988 Free PMC article.
-
C-arm calibration--is it really necessary?Med Image Comput Comput Assist Interv. 2005;8(Pt 1):639-46. doi: 10.1007/11566465_79. Med Image Comput Comput Assist Interv. 2005. PMID: 16685900
-
FTRAC--a robust fluoroscope tracking fiducial.Med Phys. 2005 Oct;32(10):3185-98. doi: 10.1118/1.2047782. Med Phys. 2005. PMID: 16279072
-
Intra-operative 3D guidance in prostate brachytherapy using a non-isocentric C-arm.Med Image Comput Comput Assist Interv. 2007;10(Pt 2):9-17. doi: 10.1007/978-3-540-75759-7_2. Med Image Comput Comput Assist Interv. 2007. PMID: 18044547
-
A Review of Fluoroscopic Image-Intensifier Artifacts and the Next Generation of Isocentric C-Arm Imaging.JBJS Rev. 2018 Dec;6(12):e4. doi: 10.2106/JBJS.RVW.18.00013. JBJS Rev. 2018. PMID: 30531202 Review. No abstract available.
Cited by
-
Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis.Med Phys. 2011 Oct;38(10):5290-302. doi: 10.1118/1.3633897. Med Phys. 2011. PMID: 21992346 Free PMC article.
-
CTREC: C-arm Tracking and Reconstruction using Elliptic Curves.Conf Comput Vis Pattern Recognit Workshops. 2008 Jun;2008:10.1109/CVPRW.2008.4563029. doi: 10.1109/CVPRW.2008.4563029. Conf Comput Vis Pattern Recognit Workshops. 2008. PMID: 26257988 Free PMC article.
-
Prostate brachytherapy seed localization using a mobile c-arm without tracking.Proc SPIE Int Soc Opt Eng. 2009 Mar 13;7261:k. doi: 10.1117/12.811225. Proc SPIE Int Soc Opt Eng. 2009. PMID: 20052296 Free PMC article.
-
Robustness and accuracy of feature-based single image 2-D-3-D registration without correspondences for image-guided intervention.IEEE Trans Biomed Eng. 2014 Jan;61(1):149-61. doi: 10.1109/TBME.2013.2278619. Epub 2013 Aug 15. IEEE Trans Biomed Eng. 2014. PMID: 23955696 Free PMC article.
-
3D-2D registration for surgical guidance: effect of projection view angles on registration accuracy.Phys Med Biol. 2014 Jan 20;59(2):271-87. doi: 10.1088/0031-9155/59/2/271. Epub 2013 Dec 19. Phys Med Biol. 2014. PMID: 24351769 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Other Literature Sources