. 2007 Mar-Apr;27(2):94-100.
doi: 10.5144/0256-4947.2007.94.

Comparison of six-minute walking tests conducted with and without supplemental oxygen in patients with chronic obstructive pulmonary disease and exercise-induced oxygen desaturation

Affiliations
Comparative Study

Comparison of six-minute walking tests conducted with and without supplemental oxygen in patients with chronic obstructive pulmonary disease and exercise-induced oxygen desaturation

Sevgi Ozalevli et al. Ann Saudi Med. 2007 Mar-Apr.

Abstract

Background: There are contradictory reports in the literature on the effects of supplemental oxygen administered before or after exercise tests. In light of this, we compared the results of 6-minute walking tests performed in room-air conditions (A6MWT) and with supplemental oxygen (O6MWT) in patients with chronic obstructive pulmonary disease (COPD) and exercise-induced oxygen desaturation.

Patients and methods: Thirty-one patients with COPD were included in the study. The A6MWT and O6MWT were performed in randomized order on each patient. During the tests, severity of dyspnea and tiring of the leg were evaluated by the Modified Borg Scale. Heart rate and pulsed oxygen saturation and blood pressure were measured by pulse oximeter.

Results: Walking distance was longer with the O6MWT than with the A6MWT (P=0.001). The O6MWT resulted in a smaller increase in dyspnea, leg fatigue, and heart rate and a smaller drop in pulsed saturation than the A6MWT (P<0.05). The walking distance with the O6MWT correlated with respiratory function and hemodynamic parameters (P<0.05).

Conclusion: The O6MWT, which produced less hemodynamic stress and was safer than the A6MWT, might provide more accurate information on exercise limitation for patients with COPD. These results suggest that the O6MWT can be used as a standard walking exercise test for patients with COPD and exercise-induced oxygen desaturation.

PubMed Disclaimer

References

    1. Poulain M, Durand F, Palomba B, Ceugniet F, Desplan J, Varray A, Prefaut C. 6-Minute walk testing is more sensitive than maximal incremental cycle testing for detecting oxygen desaturation in patients with COPD. Chest. 2003;123:1401–1407. - PubMed
    1. Jolly EC, Boscio VD, Aguirre L, Luna CM, Berensztein S, Gene RJ. Effects of supplemental oxygen during activity in patients with advanced COPD without severe resting hypoxemia. Chest. 2001;120:437–443. - PubMed
    1. Schenkel NS, Burdet L, de Murait B, Fitting JW. Oxygen saturation during daily activities in chronic obstructive pulmonary disease. Eur Respir J. 1996;9:2584–2589. - PubMed
    1. Hadeli KO, Siegel EM, Sherrill DL, Beck KC, Enright PL. Predictors of oxygen desaturation during submaximal exercise in 8,000 patients. Chest. 2001;120:88–92. - PubMed
    1. Bowen JB, Votto JJ, Thrall RS, Haggerly MC, Woolley RS, Bandyopadhyay T, ZuWallack RL. Functional status and survival following pulmonary rehabilitation. Chest. 2000;118:697–703. - PubMed

Publication types