Surgical treatment of acute type A dissecting aneurysm, with preservation of the native aortic valve and use of biologic glue. Follow-up to 6 years
- PMID: 1736003
Surgical treatment of acute type A dissecting aneurysm, with preservation of the native aortic valve and use of biologic glue. Follow-up to 6 years
Abstract
We present an analysis of 59 patients operated on between 1983 and 1987 for acute type A dissecting aneurysm with aortic valve insufficiency. The ascending aorta was replaced with a Dacron tube, the layers of the dissection were unified with gelatin-resorcine-formaldehyde glue, and the natural aortic valve was preserved. Follow-up every 6 months was subject to actuarial analysis. The hospital mortality rate was 22%. The survivors were studied for 35.9 +/- 18.6 months (mean +/- standard deviation). Eight patients died (six of cardiovascular causes, one of cancer of the colon, and one of an unknown cause). Seventeen (36.9%) had aortic insufficiency, eight mild and nine moderate to severe. Four patients with severe insufficiency had reoperation with valve replacement. Excluding patients who have died or undergone reoperation, 29 of the remainder (90.6%) are free of symptoms. The follow-up survival rate is 61% +/- 6.93% (standard error) including hospital mortality. It is 55.4% +/- 7% (standard error) excluding reoperation and 44.2% +/- 7.1% (standard error) additionally excluding modest or severe aortic insufficiency. The use of gelatin-resorcine-formal glue allowed preservation of the native aortic valve, obviating the need for anticoagulants, and no embolic or hemorrhagic episodes were registered.
Similar articles
-
The proper use of glue: a 20-year experience with the GRF glue in acute aortic dissection.J Card Surg. 1997 Mar-Apr;12(2 Suppl):243-53; discussion 253-5. J Card Surg. 1997. PMID: 9271753 Review.
-
[Surgical treatment of acute dissection of the ascending aorta (20 years experience)].Chirurgie. 1998 Jun;123(3):229-37; discussion 238. doi: 10.1016/s0001-4001(98)80114-1. Chirurgie. 1998. PMID: 9752513 French.
-
Type A acute aortic dissection: immediate and mid-term results of emergency aortic replacement with the aid of gelatin resorcin formalin glue.Ann Thorac Surg. 2004 Sep;78(3):853-7; discussion 857. doi: 10.1016/j.athoracsur.2004.03.061. Ann Thorac Surg. 2004. PMID: 15337005
-
Surgery of type A acute aortic dissection with Gelatine-Resorcine-Formol biological glue: a twelve-year experience.J Cardiovasc Surg (Torino). 1990 May-Jun;31(3):263-73. J Cardiovasc Surg (Torino). 1990. PMID: 2370256
-
Aortic dissection: anatomic types and surgical approaches.J Cardiovasc Surg (Torino). 1993 Feb;34(1):23-32. J Cardiovasc Surg (Torino). 1993. PMID: 8482700 Review.
Cited by
-
When and how to replace the aortic root in type A aortic dissection.Ann Cardiothorac Surg. 2016 Jul;5(4):377-82. doi: 10.21037/acs.2016.03.15. Ann Cardiothorac Surg. 2016. PMID: 27563551 Free PMC article.
-
An update on surgery for acute type A aortic dissection: aortic root repair, endovascular stent graft, and genetic research.Surg Today. 2009;39(4):281-9. doi: 10.1007/s00595-008-3887-3. Epub 2009 Mar 25. Surg Today. 2009. PMID: 19319633 Review.
-
Effectiveness of a new inflatable balloon device for gluing dissected layers in an experimental model of aortic dissection.Exp Clin Cardiol. 2013 Spring;18(2):166-8. Exp Clin Cardiol. 2013. PMID: 23940445 Free PMC article.
-
The use of surgical glue in acute type A aortic dissection.Gen Thorac Cardiovasc Surg. 2014 Apr;62(4):207-13. doi: 10.1007/s11748-013-0343-0. Epub 2013 Nov 21. Gen Thorac Cardiovasc Surg. 2014. PMID: 24254987 Review.
-
Aortic stump tailoring with GRF glue and a felt strip.Surg Today. 1999;29(5):484-5. doi: 10.1007/BF02483048. Surg Today. 1999. PMID: 10333427
MeSH terms
Substances
LinkOut - more resources
Medical