Recent advances in high-throughput quantitative bioanalysis by LC-MS/MS
- PMID: 17360141
- DOI: 10.1016/j.jpba.2007.02.006
Recent advances in high-throughput quantitative bioanalysis by LC-MS/MS
Abstract
Liquid chromatography linked to tandem mass spectrometry (LC-MS/MS) has played an important role in pharmacokinetics and metabolism studies at various drug development stages since its introduction to the pharmaceutical industry. This article reviews the most recent advances in sample preparation, separation, and the mass spectrometric aspects of high-throughput quantitative bioanalysis of drug and metabolites in biological matrices. Newly introduced techniques such as ultra-performance liquid chromatography with small particles (sub-2 microm) and monolithic chromatography offer improvements in speed, resolution and sensitivity compared to conventional chromatographic techniques. Hydrophilic interaction chromatography (HILIC) on silica columns with low aqueous/high organic mobile phase is emerging as a valuable supplement to the reversed-phase LC-MS/MS. Sample preparation formatted to 96-well plates has allowed for semi-automation of off-line sample preparation techniques, significantly impacting throughput. On-line solid-phase extraction (SPE) utilizing column-switching techniques is rapidly gaining acceptance in bioanalytical applications to reduce both time and labor required to produce bioanalytical results. Extraction sorbents for on-line SPE extend to an array of media including large particles for turbulent flow chromatography, restricted access materials (RAM), monolithic materials, and disposable cartridges utilizing traditional packings such as those used in Spark Holland systems. In the end, this paper also discusses recent studies of matrix effect in LC-MS/MS analysis and how to reduce/eliminate matrix effect in method development and validation.
Similar articles
-
High-throughput quantitative bioanalysis by LC/MS/MS.Biomed Chromatogr. 2000 Oct;14(6):422-9. doi: 10.1002/1099-0801(200010)14:6<422::AID-BMC25>3.0.CO;2-I. Biomed Chromatogr. 2000. PMID: 11002279 Review.
-
Ternary-column system for high-throughput direct-injection bioanalysis by liquid chromatography/tandem mass spectrometry.Rapid Commun Mass Spectrom. 2000;14(2):105-11. doi: 10.1002/(SICI)1097-0231(20000130)14:2<105::AID-RCM842>3.0.CO;2-Q. Rapid Commun Mass Spectrom. 2000. PMID: 10623938
-
High-speed gradient parallel liquid chromatography/tandem mass spectrometry with fully automated sample preparation for bioanalysis: 30 seconds per sample from plasma.Rapid Commun Mass Spectrom. 2002;16(11):1116-23. doi: 10.1002/rcm.688. Rapid Commun Mass Spectrom. 2002. PMID: 11992516
-
A novel on-line solid-phase extraction approach integrated with a monolithic column and tandem mass spectrometry for direct plasma analysis of multiple drugs and metabolites.Rapid Commun Mass Spectrom. 2005;19(22):3259-68. doi: 10.1002/rcm.2188. Rapid Commun Mass Spectrom. 2005. PMID: 16220526
-
Bioanalytical hydrophilic interaction chromatography: recent challenges, solutions and applications.Bioanalysis. 2009 Apr;1(1):239-53. doi: 10.4155/bio.09.12. Bioanalysis. 2009. PMID: 21083199 Review.
Cited by
-
Utilizing Internal Standard Responses to Assess Risk on Reporting Bioanalytical Results from Hemolyzed Samples.AAPS J. 2015 Sep;17(5):1168-76. doi: 10.1208/s12248-015-9783-z. Epub 2015 May 15. AAPS J. 2015. PMID: 25975617 Free PMC article.
-
Advances in the Study of Metabolomics and Metabolites in Some Species Interactions.Molecules. 2021 May 31;26(11):3311. doi: 10.3390/molecules26113311. Molecules. 2021. PMID: 34072976 Free PMC article. Review.
-
Platform development for expression and purification of stable isotope labeled monoclonal antibodies in Escherichia coli.MAbs. 2018 Oct;10(7):992-1002. doi: 10.1080/19420862.2018.1496879. Epub 2018 Jul 30. MAbs. 2018. PMID: 30060704 Free PMC article.
-
Dried blood spot testing for seven steroids using liquid chromatography-tandem mass spectrometry with reference interval determination in the Korean population.Ann Lab Med. 2015 Nov;35(6):578-85. doi: 10.3343/alm.2015.35.6.578. Ann Lab Med. 2015. PMID: 26354345 Free PMC article.
-
Simultaneous measurement of plasma vitamin D(3) metabolites, including 4β,25-dihydroxyvitamin D(3), using liquid chromatography-tandem mass spectrometry.Anal Biochem. 2011 Nov 1;418(1):126-33. doi: 10.1016/j.ab.2011.06.043. Epub 2011 Jul 13. Anal Biochem. 2011. PMID: 21784054 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical