. 2007 Oct;245(10):1437-40.
doi: 10.1007/s00417-007-0544-2. Epub 2007 Mar 15.

Sutureless 25-gauge vitrectomy for idiopathic macular hole repair

Affiliations

Sutureless 25-gauge vitrectomy for idiopathic macular hole repair

Stanislao Rizzo et al. Graefes Arch Clin Exp Ophthalmol. 2007 Oct.

Abstract

Background: We investigated the feasibility and safety of a 25-gauge, transconjunctival sutureless vitrectomy system for macular hole repair.

Methods: Eighty-four eyes of 77 consecutive patients with idiopathic macular hole were operated on using a transconjunctival sutureless 25-gauge vitrectomy system. A complete vitrectomy was performed using triamcinolone acetonide to visualize the vitreous gel and to remove the posterior vitreous cortex. The macular hole was covered with autologous whole blood, and the internal limiting membrane (ILM) was stained with indocyanine green. The ILM was peeled and a fluid-air exchange performed. The globe was filled with gas, and the patient was kept in a prone position for 1 week. Surgery-related complications, macular hole closure on optical coherence tomography (OCT) and visual outcome were evaluated.

Results: No intra- or postoperative complications were recorded. It was noted in particular that sclerotomies did not require sutures. No postoperative hypotony or endophthalmitis was observed. OCT showed macular hole closure in 93% of the cases. The median preoperative best-corrected visual acuity was 20/200 and improved significantly (p<0.05) to a median best-corrected visual acuity of 20/67 (median follow-up 6.5 months).

Conclusion: A 25-gauge transconjunctival sutureless vitrectomy, visualization of the vitreous with triamcinolone acetonide, protection of the macular hole with autologous whole blood and staining of the ILM using indocyanine green are safe and efficient techniques for macular hole repair.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Arch Ophthalmol. 1996 Oct;114(10):1273-5 - PubMed
    1. Am J Ophthalmol. 2006 Nov;142(5):871-3 - PubMed
    1. Retina. 2005 Feb-Mar;25(2):208-11 - PubMed
    1. Graefes Arch Clin Exp Ophthalmol. 2006 Dec;244(12):1615-9 - PubMed
    1. J Cataract Refract Surg. 2005 Jun;31(6):1198-207 - PubMed

MeSH terms

LinkOut - more resources