Design for electrospray ionization-ion mobility spectrometry
- PMID: 17367117
- DOI: 10.1021/ac062381q
Design for electrospray ionization-ion mobility spectrometry
Abstract
In this study, a new design for electrospray ionization ion mobility spectrometry (ESI-IMS) was developed. This design has two important differences in comparison to the present ESI-IMS systems. First, a few centimeters of the cell comprising the electrospray needle was located outside of the oven used for heating the IMS cell. This modification prevents prespray solvent evaporation problems such as needle clogging and disturbance of the electrospray process. Second, in addition to the drift gas, a counterflow of a heated gas (desolvation gas) was used between the counter electrode and the ion gate to speed up the desolvation process (Hill, H. H., Jr. Anal. Chem. 1998, 70, 4929-4938). This modification increased the solvent evaporation and resulted in decreasing the drift time, increasing the peak intensity and increasing the resolving power (RP) or enhancing the resolution for separation of two adjacent ion peaks. In this work, the ion mobility spectra of different compounds including ethion, malathion, metalaxyl, fenamifos, methylamine, triethylamine, tributhylamine, codeine, and morphine were obtained to confirm enhancing of the resolving power of the ion peaks by using the desolvation gas. Furthermore, the method has also been applied to obtain the figures of merit for ethion as a test compound. The linear dynamic range for ethion was in the range 50-1000 microg/L with a limit of quantification of the 50 microg/L.
Similar articles
-
Improved design for high resolution electrospray ionization ion mobility spectrometry.Talanta. 2009 Mar 15;77(5):1632-9. doi: 10.1016/j.talanta.2008.09.059. Epub 2008 Oct 17. Talanta. 2009. PMID: 19159776
-
Development of an ion mobility spectrometer for use in an atmospheric pressure ionization ion mobility spectrometer/mass spectrometer instrument for fast screening analysis.Rapid Commun Mass Spectrom. 2004;18(24):3131-9. doi: 10.1002/rcm.1738. Rapid Commun Mass Spectrom. 2004. PMID: 15565719
-
Selective method based on negative electrospray ionization ion mobility spectrometry for direct analysis of salivary thiocyanate.Anal Chem. 2010 Aug 1;82(15):6721-5. doi: 10.1021/ac101017m. Anal Chem. 2010. PMID: 20604531
-
Orbitrap mass spectrometry: instrumentation, ion motion and applications.Mass Spectrom Rev. 2008 Nov-Dec;27(6):661-99. doi: 10.1002/mas.20186. Mass Spectrom Rev. 2008. PMID: 18683895 Review.
-
Ion mobility-mass spectrometry.J Mass Spectrom. 2008 Jan;43(1):1-22. doi: 10.1002/jms.1383. J Mass Spectrom. 2008. PMID: 18200615 Review.
Cited by
-
Electrospray Ion Mobility Spectrometer Based on Flexible Printed-Circuit Board Electrodes with Improved Resolving Power.Anal Chem. 2023 Jul 18;95(28):10777-10784. doi: 10.1021/acs.analchem.3c01898. Epub 2023 Jul 5. Anal Chem. 2023. PMID: 37407429 Free PMC article.
-
Aptamer-modified carbon nanomaterial based sorption coupled to paper spray ion mobility spectrometry for highly sensitive and selective determination of methamphetamine.Mikrochim Acta. 2018 Jan 10;185(2):103. doi: 10.1007/s00604-017-2623-3. Mikrochim Acta. 2018. PMID: 29594391
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources