Conditional entropy maximization for PET image reconstruction using adaptive mesh model
- PMID: 17368841
- DOI: 10.1016/j.compmedimag.2007.01.001
Conditional entropy maximization for PET image reconstruction using adaptive mesh model
Abstract
Iterative image reconstruction algorithms have been widely used in the field of positron emission tomography (PET). However, such algorithms are sensitive to noise artifacts so that the reconstruction begins to degrade when the number of iterations is high. In this paper, we propose a new algorithm to reconstruct an image from the PET emission projection data by using the conditional entropy maximization and the adaptive mesh model. In a traditional tomography reconstruction method, the reconstructed image is directly computed in the pixel domain. Unlike this kind of methods, the proposed approach is performed by estimating the nodal values from the observed projection data in a mesh domain. In our method, the initial Delaunay triangulation mesh is generated from a set of randomly selected pixel points, and it is then modified according to the pixel intensity value of the estimated image at each iteration step in which the conditional entropy maximization is used. The advantage of using the adaptive mesh model for image reconstruction is that it provides a natural spatially adaptive smoothness mechanism. In experiments using the synthetic and clinical data, it is found that the proposed algorithm is more robust to noise compared to the common pixel-based MLEM algorithm and mesh-based MLEM with a fixed mesh structure.
Similar articles
-
PET image reconstruction: A stopping rule for the MLEM algorithm based on properties of the updating coefficients.Comput Med Imaging Graph. 2010 Mar;34(2):131-41. doi: 10.1016/j.compmedimag.2009.07.006. Epub 2009 Sep 9. Comput Med Imaging Graph. 2010. PMID: 19744826
-
Reconstruction of 2D PET data with Monte Carlo generated system matrix for generalized natural pixels.Phys Med Biol. 2006 Jun 21;51(12):3105-25. doi: 10.1088/0031-9155/51/12/008. Epub 2006 May 31. Phys Med Biol. 2006. PMID: 16757866
-
[A new Bayesian reconstruction algorithm for PET images based on correction of the detected sinogram data].Nan Fang Yi Ke Da Xue Xue Bao. 2007 Mar;27(3):325-8. Nan Fang Yi Ke Da Xue Xue Bao. 2007. PMID: 17425984 Chinese.
-
[Review on image reconstruction for positron emission tomography].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2002 Sep;19(3):496-9. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2002. PMID: 12557532 Review. Chinese.
-
Generalized approach to inverse problems in tomography: image reconstruction for spatially variant systems using natural pixels.Crit Rev Biomed Eng. 1992;20(1-2):47-71. Crit Rev Biomed Eng. 1992. PMID: 1424686 Review.
Cited by
-
Bayesian framework inspired no-reference region-of-interest quality measure for brain MRI images.J Med Imaging (Bellingham). 2017 Apr;4(2):025504. doi: 10.1117/1.JMI.4.2.025504. Epub 2017 Jun 13. J Med Imaging (Bellingham). 2017. PMID: 28630885 Free PMC article.
-
Reconstruction of positron emission tomography images using adaptive sliced remeshing strategy.J Med Imaging (Bellingham). 2021 Mar;8(2):024001. doi: 10.1117/1.JMI.8.2.024001. Epub 2021 Mar 1. J Med Imaging (Bellingham). 2021. PMID: 33681408 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources