Comparison of fast liquid chromatography/tandem mass spectrometric methods for simultaneous determination of cladribine and clofarabine in mouse plasma
- PMID: 17368998
- DOI: 10.1016/j.jpba.2007.02.007
Comparison of fast liquid chromatography/tandem mass spectrometric methods for simultaneous determination of cladribine and clofarabine in mouse plasma
Abstract
Several fast high performance liquid chromatography/atmospheric pressure ionization/tandem mass spectrometric (HPLC-API/MS/MS) methods were evaluated for the simultaneous determination of cladribine and clofarabine in mouse plasma samples. The chemical separation for analytes under reversed-phase conditions were achieved by using either ultra-performance liquid chromatography (UPLC) or micro-column HPLC coupled to either a quadrupole linear ion trap mass spectrometer (QTrap MS) or a triple quadrupole mass spectrometer. Atmospheric pressure chemical ionization (APCI) or atmospheric pressure photoionization (APPI) interfaces in the positive mode were employed prior to mass spectrometric detection. The effects of various dopant solvents on the APPI sensitivities of analytes and the internal standard were investigated. The matrix ionization suppression potential for the test compounds in plasma samples on fast HPLC-MS/MS methods was examined by a post-column infusion technique. In this work, these proposed approaches were successfully employed to determine the concentrations of cladribine and clofarabine in mouse plasma in the low ng/ml region. The mouse plasma levels of all analytes obtained by these fast HPLC-MS/MS methods were compared and found to be well correlated in terms of analytical accuracy.
Similar articles
-
Determination of a novel substance P inhibitor in human plasma by high-performance liquid chromatography with atmospheric pressure chemical ionization mass spectrometric detection using single and triple quadrupole detectors.J Chromatogr B Analyt Technol Biomed Life Sci. 2004 Aug 5;807(2):243-50. doi: 10.1016/j.jchromb.2004.04.017. J Chromatogr B Analyt Technol Biomed Life Sci. 2004. PMID: 15203036
-
Employing atmospheric pressure photoionization in liquid chromatography/tandem mass spectrometry to minimize ion suppression and matrix effects for the quantification of venlafaxine and O-desmethylvenlafaxine.Rapid Commun Mass Spectrom. 2007;21(10):1680-6. doi: 10.1002/rcm.3006. Rapid Commun Mass Spectrom. 2007. PMID: 17465011
-
Comparison of atmospheric pressure chemical ionization, electrospray ionization, and atmospheric pressure photoionization for the determination of cyclosporin A in rat plasma.Anal Chem. 2005 Jan 15;77(2):541-8. doi: 10.1021/ac040144m. Anal Chem. 2005. PMID: 15649051
-
A mixed-mode liquid chromatography-tandem mass spectrometric method for the determination of cytarabine in mouse plasma.J Chromatogr B Analyt Technol Biomed Life Sci. 2007 Jul 1;854(1-2):8-12. doi: 10.1016/j.jchromb.2007.03.034. Epub 2007 Apr 5. J Chromatogr B Analyt Technol Biomed Life Sci. 2007. PMID: 17448737
-
Supercritical fluid chromatography/tandem mass spectrometric method for analysis of pharmaceutical compounds in metabolic stability samples.J Pharm Biomed Anal. 2006 Feb 24;40(3):799-804. doi: 10.1016/j.jpba.2005.06.032. Epub 2005 Aug 10. J Pharm Biomed Anal. 2006. PMID: 16095863
Cited by
-
Quantification of clofarabine in urine and plasma by LC-MS/MS: suitable for PK study and TDM in pediatric patients with relapsed or refractory ALL.RSC Adv. 2022 Nov 18;12(51):33091-33098. doi: 10.1039/d2ra05843j. eCollection 2022 Nov 15. RSC Adv. 2022. PMID: 36425201 Free PMC article.
-
Simultaneous determination of fludarabine and clofarabine in human plasma by LC-MS/MS.J Chromatogr B Analyt Technol Biomed Life Sci. 2014 Jun 1;960:194-9. doi: 10.1016/j.jchromb.2014.04.045. Epub 2014 May 2. J Chromatogr B Analyt Technol Biomed Life Sci. 2014. PMID: 24820973 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources