Body protein index based on bioelectrical impedance analysis is a useful new marker assessing nutritional status: applications to patients with chronic renal failure on maintenance dialysis
- PMID: 17369710
- DOI: 10.1159/000100993
Body protein index based on bioelectrical impedance analysis is a useful new marker assessing nutritional status: applications to patients with chronic renal failure on maintenance dialysis
Abstract
Background: Evaluation and monitoring of nutritional status is a fundamental concept in providing nutritional care to patients with end-stage renal failure. There have been, however, few practically available indices assessing whole body protein stores of patients.
Methods: We enrolled 448 end-stage renal disease patients, 394 on maintenance hemodialysis (HD) and 54 on continuous ambulatory peritoneal dialysis (PD) in this study. 83 Age- and sex-matched subjects (controls) whose creatinine clearance was more than 70 ml/min and urinary protein excretion was less than 1.0 g/day were also recruited for comparison. To assess whole body somatic protein stores, we devised the body protein index (BPI). The volume of body protein mass was measured by multifrequency bioelectrical impedance analysis and then BPI was calculated as body protein mass (kg) divided by height in meters (m2). Based on BPI, we defined the nutritional status of the patients as normal if the value was within -10% of the mean value of control subjects, -10 to -14% as mild malnutrition, -15 to -19% as moderate malnutrition, and <-20% as severe malnutrition.
Results: The required time for measurement was 5.2 +/- 1.3 min and coefficient of variation of measurements was 0.8 +/- 0.2%. Among men the mean BPI in both HD and PD patients was significantly lower than those of control subjects (4.25 +/- 0.37, 4.38 +/- 0.34 vs. 4.72 +/- 0.37 kg/m2, p < 0.001). In women, BPI was significantly lower in HD patients than in control subjects (3.65 +/- 0.34 vs. 4.00 +/- 0.34 kg/m2, p < 0.033), whereas only a nonsignificant lower tendency was found in PD patients (3.83 +/- 0.39 kg/m2, p = 0.067). There were no significant differences in BPI values between diabetic and non-diabetic subjects, both in men (4.26 +/- 0.41 vs. 4.25 +/- 0.36 kg/m2) and women (3.69 +/- 0.36 vs. 3.65 +/- 0.34 kg/m2). Based on BPI nutritional categories, 113 (28.7%) of all HD patients were classified as having mild malnutrition, 57 (14.5%) as having moderate malnutrition, 40 (10.1%) as having severe malnutrition, and 184 (46.7%) were classified as normal. The patients of longer dialysis history groups showed a tendency of lower BPI compared to those of shorter dialysis history groups (p < 0.05), although the ages of the patients of the two groups did not significantly differ. No correlations were found between BPI and serum albumin or transferrin concentrations. Only weak correlations were found with albumin in male and transferrin in female HD patients.
Conclusion: BPI calculated from measurement of multifrequency bioelectrical impedance analysis could evaluate whole body somatic protein stores, and is a potentially useful new marker assessing nutritional status in patients with chronic renal failure. Decreased body somatic protein stores, mainly due to muscle wasting, was prevalent in end-stage renal failure patients on maintenance dialysis.
Similar articles
-
[Nutritional status evaluation in maintenance hemodialysis patients].Rev Med Chir Soc Med Nat Iasi. 2008 Apr-Jun;112(2):343-50. Rev Med Chir Soc Med Nat Iasi. 2008. PMID: 19295002 Romanian.
-
Reliability of bioelectrical impedance analysis in the evaluation of the nutritional status of hemodialysis patients - a comparison with Mini Nutritional Assessment.Transplant Proc. 2013;45(10):3485-8. doi: 10.1016/j.transproceed.2013.08.096. Transplant Proc. 2013. PMID: 24314938
-
Body fluid volume and nutritional status in hemodialysis: vector bioelectric impedance analysis.Clin Nephrol. 2010 Apr;73(4):300-8. Clin Nephrol. 2010. PMID: 20353738
-
Use of bioelectrical impedance techniques for monitoring nutritional status in patients on maintenance dialysis.J Ren Nutr. 2000 Jul;10(3):116-24. doi: 10.1053/jren.2000.7916. J Ren Nutr. 2000. PMID: 10921532 Review.
-
Albumin and amino acid levels as markers of adequacy in continuous ambulatory peritoneal dialysis.Perit Dial Int. 1994;14 Suppl 3:S123-32. Perit Dial Int. 1994. PMID: 7948261 Review.
Cited by
-
Positive association of vigorous and moderate physical activity volumes with skeletal muscle mass but not bone density or metabolism markers in hemodialysis patients.Int Urol Nephrol. 2014 Mar;46(3):633-9. doi: 10.1007/s11255-014-0662-9. Epub 2014 Feb 13. Int Urol Nephrol. 2014. PMID: 24526334
-
Progressive inflammation and wasting in patients with ESRD.Clin J Am Soc Nephrol. 2014 Feb;9(2):225-6. doi: 10.2215/CJN.12541213. Epub 2014 Jan 23. Clin J Am Soc Nephrol. 2014. PMID: 24458072 Free PMC article. No abstract available.
-
Metabolic Effects on Body Components After a Three-Month Physical Intervention in Overweight Medical Staff.Cureus. 2021 Oct 25;13(10):e19027. doi: 10.7759/cureus.19027. eCollection 2021 Oct. Cureus. 2021. PMID: 34824937 Free PMC article.
-
Risk factors for the development of intradialytic hypotension in patients undergoing maintenance hemodialysis.Int Urol Nephrol. 2025 Jul 11. doi: 10.1007/s11255-025-04645-5. Online ahead of print. Int Urol Nephrol. 2025. PMID: 40646390
-
Association between Serum Zinc Levels and Clinical Index or the Body Composition in Incident Hemodialysis Patients.Nutrients. 2020 Oct 19;12(10):3187. doi: 10.3390/nu12103187. Nutrients. 2020. PMID: 33086501 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical