Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1992 Jan 18;304(6820):159-62.
doi: 10.1136/bmj.304.6820.159.

Quality of data in the Manchester orthopaedic database

Affiliations

Quality of data in the Manchester orthopaedic database

J L Barrie et al. BMJ. .

Abstract

Objective: To determine the completeness and accuracy of data in a computerised clinical information system (Manchester orthopaedic database) in comparison with the data available through the Hospital Activity Analysis.

Design: Retrospective review of case notes, computer data, and Hospital Activity Analysis data.

Setting: Orthopaedic unit in a district general hospital in Manchester.

Subjects: 200 random patient records distributed through the period of use of the computer system (1 October 1988 to 31 March 1990) and 121 records for random admissions between 1 April 1989 and 31 March 1990, 71 of which were included in the previous sample.

Main outcome measures: Conformity of the computer record key words and Hospital Activity Analysis codes to an ideal key word record and ideal code record drawn up by one investigator from the clinical notes; overall quality (completeness times accuracy).

Results: Overall completeness of the data in the orthopaedic database was 62% and the accuracy was 96%. Completeness improved after feedback to doctors on the use of key words in regular audit meetings. Completeness was higher in inpatient than outpatient records (69.9% v 53.7%, p less than 0.001) and when a new key word was required compared with missing and incorrect key words (both p less than 0.001). Completeness was lower when the key word was required of a senior registrar (p less than 0.05). Accuracy was not significantly different. The completeness of Hospital Activity Analysis data was 90.5% and accuracy 69.5%. Thus the overall data quality was similar in both systems.

Conclusions: Even in a system designed for simple and efficient data capture, compliance by users was poor. Accuracy was high, suggesting that users understood the principles of data entry. Completeness of data capture can be improved by providing feedback to users on use of the system and performance. Improvements in future versions of the software should improve performance.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Br Med J (Clin Res Ed). 1988 Mar 5;296(6623):687-91 - PubMed
    1. J R Soc Med. 1987 Mar;80(3):157-61 - PubMed
    1. Obstet Gynecol. 1989 May;73(5 Pt 1):803-7 - PubMed
    1. Orthop Clin North Am. 1986 Oct;17(4):527-39 - PubMed
    1. Arch Dis Child. 1985 Jun;60(6):593-4 - PubMed

MeSH terms

LinkOut - more resources