Integration of a nanoporous platinum thin film into a microfluidic system for non-enzymatic electrochemical glucose sensing
- PMID: 17372368
- DOI: 10.2116/analsci.23.277
Integration of a nanoporous platinum thin film into a microfluidic system for non-enzymatic electrochemical glucose sensing
Abstract
In this paper, we describe an amperometric-type enzymeless glucose sensing system based on a nanoporous platinum (Pt) electrode embedded in a microfluidic chip. This microchip system is comprised of a microfluidic transport channel network and a miniaturized electrochemical cell for nonenzymatic glucose sensing. Sample and buffer solutions were transferred to the cell by programmed electroosmotic flow (EOF). A nanoporous Pt electrode with the roughness factor of 200.6 was utilized to determine glucose concentrations in phosphate buffered saline (PBS) by the direct oxidation of glucose, without any separation process. The sensitivity of the developed system is 1.65 microA cm-2 mM-1 in the glucose concentration range from 1-10 mM in PBS.
Similar articles
-
Nanoporous platinum solid-state reference electrode with layer-by-layer polyelectrolyte junction for pH sensing chip.Lab Chip. 2011 Feb 21;11(4):664-71. doi: 10.1039/c0lc00293c. Epub 2010 Dec 7. Lab Chip. 2011. PMID: 21135953
-
Nanoporous cerium oxide thin film for glucose biosensor.Biosens Bioelectron. 2009 Mar 15;24(7):2040-5. doi: 10.1016/j.bios.2008.10.032. Epub 2008 Nov 17. Biosens Bioelectron. 2009. PMID: 19112013
-
A droplet-based microfluidic electrochemical sensor using platinum-black microelectrode and its application in high sensitive glucose sensing.Biosens Bioelectron. 2014 May 15;55:106-12. doi: 10.1016/j.bios.2013.12.002. Epub 2013 Dec 10. Biosens Bioelectron. 2014. PMID: 24368227
-
A Review on Microfluidic Paper-Based Analytical Devices for Glucose Detection.Sensors (Basel). 2016 Dec 8;16(12):2086. doi: 10.3390/s16122086. Sensors (Basel). 2016. PMID: 27941634 Free PMC article. Review.
-
Electrochemical techniques for microfluidic applications.Electrophoresis. 2008 May;29(9):1787-800. doi: 10.1002/elps.200700581. Electrophoresis. 2008. PMID: 18384068 Review.
Cited by
-
Porous Platinum Black-Coated Minimally Invasive Microneedles for Non-Enzymatic Continuous Glucose Monitoring in Interstitial Fluid.Nanomaterials (Basel). 2020 Dec 25;11(1):37. doi: 10.3390/nano11010037. Nanomaterials (Basel). 2020. PMID: 33375593 Free PMC article.
-
Fabrication of a microneedle/CNT hierarchical micro/nano surface electrochemical sensor and its in-vitro glucose sensing characterization.Sensors (Basel). 2013 Dec 4;13(12):16672-81. doi: 10.3390/s131216672. Sensors (Basel). 2013. PMID: 24304643 Free PMC article.
-
Interplay of Effective Surface Area, Mass Transport, and Electrochemical Features in Nanoporous Nucleic Acid Sensors.Anal Chem. 2020 Aug 4;92(15):10751-10758. doi: 10.1021/acs.analchem.0c02104. Epub 2020 Jul 14. Anal Chem. 2020. PMID: 32600033 Free PMC article.
-
Nanoporous membranes for medical and biological applications.Wiley Interdiscip Rev Nanomed Nanobiotechnol. 2009 Sep-Oct;1(5):568-81. doi: 10.1002/wnan.50. Wiley Interdiscip Rev Nanomed Nanobiotechnol. 2009. PMID: 20049818 Free PMC article. Review.
-
Electrically Guided DNA Immobilization and Multiplexed DNA Detection with Nanoporous Gold Electrodes.Nanomaterials (Basel). 2018 May 21;8(5):351. doi: 10.3390/nano8050351. Nanomaterials (Basel). 2018. PMID: 29883441 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources