Parallel magnetic resonance imaging
- PMID: 17374908
- DOI: 10.1088/0031-9155/52/7/R01
Parallel magnetic resonance imaging
Abstract
Parallel imaging has been the single biggest innovation in magnetic resonance imaging in the last decade. The use of multiple receiver coils to augment the time consuming Fourier encoding has reduced acquisition times significantly. This increase in speed comes at a time when other approaches to acquisition time reduction were reaching engineering and human limits. A brief summary of spatial encoding in MRI is followed by an introduction to the problem parallel imaging is designed to solve. There are a large number of parallel reconstruction algorithms; this article reviews a cross-section, SENSE, SMASH, g-SMASH and GRAPPA, selected to demonstrate the different approaches. Theoretical (the g-factor) and practical (coil design) limits to acquisition speed are reviewed. The practical implementation of parallel imaging is also discussed, in particular coil calibration. How to recognize potential failure modes and their associated artefacts are shown. Well-established applications including angiography, cardiac imaging and applications using echo planar imaging are reviewed and we discuss what makes a good application for parallel imaging. Finally, active research areas where parallel imaging is being used to improve data quality by repairing artefacted images are also reviewed.
Similar articles
-
Recent advances in image reconstruction, coil sensitivity calibration, and coil array design for SMASH and generalized parallel MRI.MAGMA. 2002 Jan;13(3):158-63. doi: 10.1007/BF02678591. MAGMA. 2002. PMID: 11755091
-
A generalized approach to parallel magnetic resonance imaging.Med Phys. 2001 Aug;28(8):1629-43. doi: 10.1118/1.1386778. Med Phys. 2001. PMID: 11548932
-
Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.Magn Reson Med. 1997 Oct;38(4):591-603. doi: 10.1002/mrm.1910380414. Magn Reson Med. 1997. PMID: 9324327
-
Non-Cartesian parallel imaging reconstruction.J Magn Reson Imaging. 2014 Nov;40(5):1022-40. doi: 10.1002/jmri.24521. Epub 2014 Jan 10. J Magn Reson Imaging. 2014. PMID: 24408499 Free PMC article. Review.
-
Autocalibrated coil sensitivity estimation for parallel imaging.NMR Biomed. 2006 May;19(3):316-24. doi: 10.1002/nbm.1048. NMR Biomed. 2006. PMID: 16705632 Review.
Cited by
-
Multi-site benchmarking of clinical 13C RF coils at 3T.J Magn Reson. 2020 Sep;318:106798. doi: 10.1016/j.jmr.2020.106798. Epub 2020 Jul 27. J Magn Reson. 2020. PMID: 32755748 Free PMC article.
-
Accelerating acquisition strategies for low-frequency conductivity imaging using MREIT.Phys Med Biol. 2018 Feb 13;63(4):045011. doi: 10.1088/1361-6560/aaa8d2. Phys Med Biol. 2018. PMID: 29345626 Free PMC article.
-
An integrated approach to correction for off-resonance effects and subject movement in diffusion MR imaging.Neuroimage. 2016 Jan 15;125:1063-1078. doi: 10.1016/j.neuroimage.2015.10.019. Epub 2015 Oct 20. Neuroimage. 2016. PMID: 26481672 Free PMC article.
-
High spatial resolution compressed sensing (HSPARSE) functional MRI.Magn Reson Med. 2016 Aug;76(2):440-55. doi: 10.1002/mrm.25854. Epub 2015 Oct 29. Magn Reson Med. 2016. PMID: 26511101 Free PMC article.
-
Magnetic Resonance Imaging of the Liver (Including Biliary Contrast Agents) Part 1: Technical Considerations and Contrast Materials.Semin Roentgenol. 2016 Oct;51(4):308-316. doi: 10.1053/j.ro.2016.05.015. Epub 2016 May 30. Semin Roentgenol. 2016. PMID: 27743567 Free PMC article. Review. No abstract available.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical