MR arthrography of the shoulder, hip, and wrist: evaluation of contrast dynamics and image quality with increasing injection-to-imaging time
- PMID: 17377051
- DOI: 10.2214/AJR.06.0719
MR arthrography of the shoulder, hip, and wrist: evaluation of contrast dynamics and image quality with increasing injection-to-imaging time
Abstract
Objective: The purpose of our study was to investigate the contrast dynamics and the relationship between visualization of intraarticular structures and time elapsed between intraarticular injection of contrast agent and MRI in symptomatic patients referred for MR arthrography of the shoulder, hip, and wrist.
Subjects and methods: Our local ethics committees and the national drug administration approved this multicentric study. We prospectively studied 11 shoulders, 11 hips, and 10 wrists. After the intraarticular gadolinium injection, patients underwent a baseline MR arthrography protocol (time point [TP] 1) and subsequent MRI at another four time points (TP 2-TP 5) up to 240 minutes. The course of contrast-to-noise ratio (CNR) over time was calculated. Three observers assessed the degree of visualization of different intraarticular structures and the overall image quality at each time point using a 3-point scale and a 5-point scale, respectively.
Results: For all joints, CNR measurements showed peak CNR at TP 1 (21 minutes) and TP 2 (45 minutes) with a subsequent, near-logarithmic decline of CNR values over time. Visualization of different anatomic structures decreased over time. Overall image quality was insufficient for diagnostic purposes at TP 3 (96 minutes) in three (27%) of 11 shoulders and in three (27%) of 11 hips. In two (20%) of 10 wrists, image quality was insufficient at TP 2 (45 minutes).
Conclusion: For MR arthrography, the degree of visualization of intraarticular structures depends on the time elapsed between contrast injection and MRI. MR arthrography of the shoulder and hip should be performed within 90 minutes, and MR arthrography of the wrist should be performed within 45 minutes, after intraarticular injection.
Comment in
-
[MRI/CT arthrography: no superfluous examination].Radiologe. 2007 Nov;47(11):959. doi: 10.1007/s00117-007-1579-4. Radiologe. 2007. PMID: 17955206 German. No abstract available.
Similar articles
-
Ultrasound-guided gadolinium joint injections for magnetic resonance arthrography.J Clin Ultrasound. 2011 Jan;39(1):6-11. doi: 10.1002/jcu.20753. Epub 2010 Nov 12. J Clin Ultrasound. 2011. PMID: 21136580
-
MR arthrography of the shoulder with gadopentetate dimeglumine: influence of concentration, iodinated contrast material, and time on signal intensity.AJR Am J Roentgenol. 1994 Sep;163(3):621-3. doi: 10.2214/ajr.163.3.8079856. AJR Am J Roentgenol. 1994. PMID: 8079856
-
Augmented reality visualization with use of image overlay technology for MR imaging-guided interventions: assessment of performance in cadaveric shoulder and hip arthrography at 1.5 T.Radiology. 2012 Oct;265(1):254-9. doi: 10.1148/radiol.12112640. Epub 2012 Jul 27. Radiology. 2012. PMID: 22843764 Free PMC article.
-
Magnetic resonance knee arthrography. Enhanced contrast by gadolinium complex in the rabbit and in humans.Acta Orthop Scand Suppl. 1990;240:1-57. Acta Orthop Scand Suppl. 1990. PMID: 2281774 Review.
-
[MR arthrography].J Radiol. 2000 Sep;81(9):945-52. J Radiol. 2000. PMID: 10992091 Review. French.
Cited by
-
MRI of weight bearing and movement.Osteoarthritis Cartilage. 2012 Feb;20(2):69-78. doi: 10.1016/j.joca.2011.11.003. Epub 2011 Nov 17. Osteoarthritis Cartilage. 2012. PMID: 22138286 Free PMC article. Review.
-
Magnetic resonance arthrography of the hip: technique and spectrum of findings in younger patients.Insights Imaging. 2010 May;1(2):72-82. doi: 10.1007/s13244-010-0023-x. Epub 2010 Jun 8. Insights Imaging. 2010. PMID: 22347907 Free PMC article.
-
[Magnetic resonance arthrography].Radiologe. 2020 Mar;60(3):273-284. doi: 10.1007/s00117-020-00648-8. Radiologe. 2020. PMID: 32067106 Review. German.
-
Diagnostic performance of CT-arthrography and 1.5T MR-arthrography for the assessment of glenohumeral joint cartilage: a comparative study with arthroscopic correlation.Eur Radiol. 2015 Apr;25(4):961-9. doi: 10.1007/s00330-014-3469-2. Epub 2014 Nov 8. Eur Radiol. 2015. PMID: 25377772
-
Divalent Manganese Complexes as Potential Replacements for Gadolinium-Based Contrast Agents.Invest Radiol. 2024 Feb 1;59(2):187-196. doi: 10.1097/RLI.0000000000001053. Epub 2023 Dec 1. Invest Radiol. 2024. PMID: 38038701 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical