Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2007 Apr;188(4):1131-7.
doi: 10.2214/AJR.06.0902.

Homogeneous enhancement in pediatric thoracic CT aortography using a novel and reproducible method: contrast-covering time

Affiliations
Comparative Study

Homogeneous enhancement in pediatric thoracic CT aortography using a novel and reproducible method: contrast-covering time

I-Chen Tsai et al. AJR Am J Roentgenol. 2007 Apr.

Abstract

Objective: This study compares the empiric setting and contrast-covering time (CCT) concept for i.v. contrast injection in pediatric thoracic CT aortography.

Subjects and methods: A total of 113 pediatric patients referred for thoracic CT aortography were classified into four groups: group 1 (1-5 years old, CCT), group 2A (6-10 years old, CCT), group 2B (6-10 years old, empiric setting), and group 3 (11-15 years old, CCT). The CT attenuation values from the left common carotid artery to the descending aorta were recorded every 0.5 second. The quantitative bolus geometric analysis of each group included average enhancement, SD within the patient, and slope of enhancement. Groups 2A and 2B were compared to determine whether better bolus geometry could be obtained with the CCT concept than with the traditional empiric setting. Groups 1, 2A, and 3 were compared to determine whether homogeneous bolus geometry could be obtained in different age groups.

Results: More homogeneous enhancement was obtained with the CCT concept than the empiric setting with a smaller SD of enhancement (25.5 +/- 8.5 H vs 49.3 +/- 16.2 H, p < 0.001). Furthermore, in the three different age groups (groups 1, 2A, and 3) examined using the CCT concept, there was no significant difference in the average enhancement (415.7 +/- 83.6 H, 422.8 +/- 97.1 H, 392.0 +/- 78.5 H, respectively; all p > 0.05), SD of enhancement (28.5 +/- 9.8 H, 25.5 +/- 8.5 H, 28.5 +/- 14.6 H, respectively; all p > 0.05), or enhancement slopes (-5.6 +/- 18.0 H, -2.7 +/- 10.7 H, -5.4 +/- 12.3 H, respectively; all p > 0.05).

Conclusion: The CCT concept yields more homogeneous enhancement than the empiric setting. It also can routinely obtain homogeneous bolus geometry in patients in different age groups.

PubMed Disclaimer

Publication types