EchoComTEE - a simulator for transoesophageal echocardiography
- PMID: 17381570
- DOI: 10.1111/j.1365-2044.2007.04978.x
EchoComTEE - a simulator for transoesophageal echocardiography
Abstract
Transoesophageal echocardiography (TOE) requires extensive hands-on training, and it is for this purpose we have designed EchoComTEE, a simulator for TOE. It consists of a manikin and dummy probe; according to the position of the dummy probe (tracked by an electromagnetic sensor), two-dimensional (2D) images are calculated from three-dimensional (3D) data sets. Echocardiographic images are presented side-by-side with a virtual scene consisting of a 3D heart, probe tip and image plane. In this way the trainee is provided with visual feed-back of the relationship between echocardiogram and image plane position. We evaluated the simulator using a standardised questionnaire. Twenty-five experts and 31 novice users participated in the study. Most experts graded the simulator as realistic and all recommended its use for training. Most novice users felt the simulator supported spatial orientation during TOE and, as anaesthetists often do not have training in transthoracic echocardiography, in this group the TOE simulator might be particularly useful.
Similar articles
-
Computer-based training in two-dimensional echocardiography using an echocardiography simulator.J Am Soc Echocardiogr. 2005 Apr;18(4):362-6. doi: 10.1016/j.echo.2004.10.025. J Am Soc Echocardiogr. 2005. PMID: 15846165
-
Augmented reality simulator for training in two-dimensional echocardiography.Comput Biomed Res. 2000 Feb;33(1):11-22. doi: 10.1006/cbmr.1999.1527. Comput Biomed Res. 2000. PMID: 10772781
-
Simulation of congenital heart defects: a novel way of training in echocardiography.Heart. 2009 Apr;95(8):636-41. doi: 10.1136/hrt.2008.156919. Epub 2009 Jan 8. Heart. 2009. PMID: 19131439
-
Innovative transesophageal echocardiography training and competency assessment for Chinese anesthesiologists: role of transesophageal echocardiography simulation training.Curr Opin Anaesthesiol. 2012 Dec;25(6):686-91. doi: 10.1097/ACO.0b013e32835a10fb. Curr Opin Anaesthesiol. 2012. PMID: 23079579 Review.
-
Simulation for transthoracic echocardiography of aortic valve.Ann Card Anaesth. 2016 Jul-Sep;19(3):498-504. doi: 10.4103/0971-9784.185541. Ann Card Anaesth. 2016. PMID: 27397455 Free PMC article. Review.
Cited by
-
Virtual Neonatal Echocardiographic Training System (VNETS): An Echocardiographic Simulator for Training Basic Transthoracic Echocardiography Skills in Neonates and Infants.IEEE J Transl Eng Health Med. 2018 Nov 1;6:4700113. doi: 10.1109/JTEHM.2018.2878724. eCollection 2018. IEEE J Transl Eng Health Med. 2018. PMID: 30464863 Free PMC article.
-
Simulation-based transthoracic echocardiography: "An anesthesiologist's perspective".Ann Card Anaesth. 2016 Jul-Sep;19(3):511-5. doi: 10.4103/0971-9784.185544. Ann Card Anaesth. 2016. PMID: 27397457 Free PMC article. Review.
-
Preliminary report on use of 3-dimensional computed tomographic images in a disease-based transesophageal echocardiographic simulation system.Tex Heart Inst J. 2013;40(3):250-5. Tex Heart Inst J. 2013. PMID: 23914013 Free PMC article.
-
A narrative review of Neonatal Echocardiography Simulator Training (NEST): role of simulators in acquiring neonatal echocardiography skills effectively.Pediatr Res. 2025 Aug 12. doi: 10.1038/s41390-025-04321-5. Online ahead of print. Pediatr Res. 2025. PMID: 40796668 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources