Bacterial contamination of platelet concentrates: results of a prospective multicenter study comparing pooled whole blood-derived platelets and apheresis platelets
- PMID: 17381623
- DOI: 10.1111/j.1537-2995.2007.01166.x
Bacterial contamination of platelet concentrates: results of a prospective multicenter study comparing pooled whole blood-derived platelets and apheresis platelets
Abstract
Background: The GERMS Group initiated a prospective multicenter study to assess prevalence and nature of bacterial contamination of pooled buffy-coat platelet concentrates (PPCs) and apheresis platelet concentrates (APCs) by routine screening with a bacterial culture system.
Study design and methods: In nine centers overall, 52,243 platelet (PLT) concentrates (15,198 APCs, 37,045 PPCs) were analyzed by aerobic and anaerobic cultures (BacT/ALERT, bioMérieux).
Results: In 135 PLT concentrates (PCs; 0.26%), bacteria could be identified in the first culture (0.4% for APCs vs. 0.2% for PPCs; p < 0.001). In 37 (0.07%) of these PC units, the same bacteria strain could be identified in a second culture from the sample bag and/or the PC unit. The rate of confirmed-positive units did not differ significantly between APC (0.09%; 1/1169) and PPC units (0.06%; 1/1544). Bacteria from skin flora (Propionibacterium acnes, Staphylococcus epidermidis) were the most prevalent contaminants. Median times to first positive culture from start of incubation were 0.7 and 3.7 days in aerobic and anaerobic cultures for confirmed-positive units. With a "negative-to-date" issue strategy, most PC units (55%) had already been issued by time of the first positive culture.
Conclusion: The rate of confirmed bacterial contamination of PC units was low. Nevertheless, clinicians must be aware of this risk. The risk of bacterial contamination does not warrant universal preference of APCs. It must be questioned whether routine bacterial screening by a culture method can sufficiently prevent contaminated products from being transfused due to the delay until a positive signal in the culture system and due to false-negative results.
Similar articles
-
Detection of bacterial contamination of apheresis platelets in a Chinese Blood Center.Transfus Med. 2009 Dec;19(6):357-62. doi: 10.1111/j.1365-3148.2009.00948.x. Epub 2009 Aug 28. Transfus Med. 2009. PMID: 19719475
-
Six years' experience of using the BacT/ALERT system to screen all platelet concentrates, and additional testing of outdated platelet concentrates to estimate the frequency of false-negative results.Vox Sang. 2005 Feb;88(2):93-7. doi: 10.1111/j.1423-0410.2005.00596.x. Vox Sang. 2005. PMID: 15720606
-
False-positive alarms for bacterial screening of platelet concentrates with BacT/ALERT new-generation plastic bottles: a multicenter pilot study.Transfusion. 2005 Aug;45(8):1267-74. doi: 10.1111/j.1537-2995.2005.00194.x. Transfusion. 2005. PMID: 16078911
-
Bacterial contamination of platelets.Transfus Apher Sci. 2010 Feb;42(1):71-82. doi: 10.1016/j.transci.2009.10.009. Epub 2009 Nov 24. Transfus Apher Sci. 2010. PMID: 19939734 Review.
-
A critical comparison of platelet preparation methods.Curr Opin Hematol. 2006 Sep;13(5):323-30. doi: 10.1097/01.moh.0000239703.40297.a5. Curr Opin Hematol. 2006. PMID: 16888436 Review.
Cited by
-
Supply with Platelet Concentrates from the Point of View of a Blood Donation Service of the Bavarian Red Cross.Transfus Med Hemother. 2008;35(2):114-116. doi: 10.1159/000119114. Epub 2008 Mar 19. Transfus Med Hemother. 2008. PMID: 21512638 Free PMC article.
-
Complete Genome Sequences of Two Distinct Strains of Serratia marcescens Isolated from Contaminated Platelet Concentrates from Canadian Donors.Microbiol Resour Announc. 2020 Oct 8;9(41):e00829-20. doi: 10.1128/MRA.00829-20. Microbiol Resour Announc. 2020. PMID: 33033127 Free PMC article.
-
Proceedings of a Consensus Conference: pathogen inactivation-making decisions about new technologies.Transfus Med Rev. 2008 Jan;22(1):1-34. doi: 10.1016/j.tmrv.2007.09.001. Transfus Med Rev. 2008. PMID: 18063190 Free PMC article. Review.
-
Implementation of Bacterial Detection Methods into Blood Donor Screening - Overview of Different Technologies.Transfus Med Hemother. 2011;38(4):259-265. doi: 10.1159/000330305. Epub 2011 Jul 7. Transfus Med Hemother. 2011. PMID: 22016697 Free PMC article.
-
Pathogen Reduction in Blood Products: What's Behind These Techniques?Transfus Med Hemother. 2011;38(1):5-6. doi: 10.1159/000324457. Transfus Med Hemother. 2011. PMID: 21779201 Free PMC article. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous