Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2007 Jun;33(4):435-40.
doi: 10.1016/j.burns.2006.08.010. Epub 2007 Mar 26.

Recombinant FVIIa decreases perioperative blood transfusion requirement in burn patients undergoing excision and skin grafting--results of a single centre pilot study

Affiliations
Randomized Controlled Trial

Recombinant FVIIa decreases perioperative blood transfusion requirement in burn patients undergoing excision and skin grafting--results of a single centre pilot study

Pär Ingemar Johansson et al. Burns. 2007 Jun.

Abstract

Background: Excision of burn wounds is frequently associated with a large volume of blood loss requiring allogeneic blood transfusion. We conducted a pilot study to investigate the effect of activated recombinant coagulation factor VII (rFVIIa) on the reduction of blood transfusion requirements in burn patients undergoing excision and skin grafting.

Methods: Eighteen consecutive patients scheduled for the surgery were randomised to receive either placebo or 40 microg/kg rFVIIa administered at first skin incision, and a second dose (40 microg/kg) at 90 min later. Blood transfusion requirements during, and up to 24h post-surgery per patient and percentage full thickness wound excised were compared. In addition, postoperative complications commonly seen in patients with burns as well as adverse events related to rFVIIa were monitored.

Results: rFVIIa significantly decreased the total number of units of blood components transfused per patient and percentage full thickness burn wound excised compared with placebo (0.9 versus 2.2, p=0.0013) including significant fewer red blood cell units (0.5 versus 1.1, p=0.004). We further observed a trend towards improved graft survival (p=0.1) and a reduction in multiple organ failures (p=0.08) in the rFVIIa-treated group. There were no adverse events, in particular thromboembolic events.

Conclusion: rFVIIa might be useful in decreasing blood transfusion requirements in burn patients undergoing excision and skin grafting.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources