Improving the detection limits of antispasmodic drugs electrodes by using modified membrane sensors with inner solid contact
- PMID: 17383844
- DOI: 10.1016/j.jpba.2007.01.018
Improving the detection limits of antispasmodic drugs electrodes by using modified membrane sensors with inner solid contact
Abstract
Three coated wire electrodes (CWEs) for the antispasmodic drugs; dicyclomine (Dc), mebeverine (Mv) and drotaverine (Dv) hydrochlorides were developed. Each electrode based on ion-associate of a heteropoly anion with the drug cation incorporated in membrane sensor modified with graphite and deposited on silver internal solid contact. The influence of addition of graphite to the membranes and the type of the internal solid contact on the potentiometric responses of the electrodes was investigated. The characteristics of the new electrodes were compared to the characteristics of previously reported traditional liquid inner contact electrodes of the same drugs. The lower detection limits of the proposed electrodes were somewhat better than those observed with the corresponding liquid contact ISEs and reached (1.2-2.0)x10(-7)M. The potentiometric selectivity of the CWEs revealed a significant improvement and much faster response times compared to the liquid contact ISEs. The practical utility of each electrode has been demonstrated by using it successfully in potentiometric determination of its respective drug in pharmaceutical preparations both in batch and flow injection conditions. Each electrode was also used as an indicator electrode in the potentiometric titration of the drug against standard silicotungstic acid and in potentiometric determination of the drug concentration in urine samples.
Similar articles
-
Novel lipoate-selective membrane sensor for the flow injection determination of alpha-lipoic acid in pharmaceutical preparations and urine.Talanta. 2008 Feb 15;74(5):1113-21. doi: 10.1016/j.talanta.2007.08.008. Epub 2007 Aug 17. Talanta. 2008. PMID: 18371758
-
Characteristics of new composite- and classical potentiometric sensors for the determination of pioglitazone in some pharmaceutical formulations.J Pharm Biomed Anal. 2008 Sep 10;48(1):57-61. doi: 10.1016/j.jpba.2008.04.029. Epub 2008 May 7. J Pharm Biomed Anal. 2008. PMID: 18555633
-
Novel and selective potentiometric membrane sensor for amiloride determination in pharmaceutical compounds and urine.J Pharm Biomed Anal. 2008 Aug 5;47(4-5):802-6. doi: 10.1016/j.jpba.2008.03.024. Epub 2008 Mar 29. J Pharm Biomed Anal. 2008. PMID: 18448303
-
Recent advances on potentiometric membrane sensors for pharmaceutical analysis.Comb Chem High Throughput Screen. 2011 May;14(4):284-302. doi: 10.2174/138620711795222437. Comb Chem High Throughput Screen. 2011. PMID: 21375501 Review.
-
Cyclodextrins Based Electrochemical Sensors for Biomedical and Pharmaceutical Analysis.Curr Med Chem. 2017;24(22):2359-2391. doi: 10.2174/0929867323666161213101407. Curr Med Chem. 2017. PMID: 27978804 Review.
Cited by
-
First derivative synchronous fluorescence spectroscopy for the simultaneous determination of sulpiride and mebeverine hydrochloride in their combined tablets and application to real human plasma.J Fluoresc. 2010 Nov;20(6):1275-85. doi: 10.1007/s10895-010-0679-0. Epub 2010 Jul 7. J Fluoresc. 2010. PMID: 20607372
-
Two fabricated carbon paste electrodes for novel potentiometric determination of probenecid in dosage form and human plasma.Sci Rep. 2022 Nov 28;12(1):20418. doi: 10.1038/s41598-022-24920-0. Sci Rep. 2022. PMID: 36443448 Free PMC article.
-
Electrochemically-selective electrode for quantification of dorzolamide in bulk drug substance and dosage form.BMC Chem. 2023 Aug 21;17(1):103. doi: 10.1186/s13065-023-01021-1. BMC Chem. 2023. PMID: 37605267 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources