Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 May;53(5):916-21.
doi: 10.1373/clinchem.2006.081166. Epub 2007 Mar 23.

Diagnostic accuracy of blood lactate-to-pyruvate molar ratio in the differential diagnosis of congenital lactic acidosis

Affiliations

Diagnostic accuracy of blood lactate-to-pyruvate molar ratio in the differential diagnosis of congenital lactic acidosis

François-Guillaume Debray et al. Clin Chem. 2007 May.

Abstract

Background: Although the blood lactate-to-pyruvate (L:P) molar ratio is used to distinguish between pyruvate dehydrogenase deficiency (PDH-D) and other causes of congenital lactic acidosis (CLA), its diagnostic accuracy for differentiating between these 2 types of CLA has not been evaluated formally.

Methods: We conducted a retrospective study of all patients followed for mitochondrial diseases between 1985 and 2005 in a tertiary care pediatric hospital.

Results: At the recommended cut point of approximately 25, individual median L:P ratio demonstrated low sensitivity and specificity (77% and 91%, respectively) for differentiating between patients with enzymatically proven PDH-D (n = 11) and those with mitochondrial disease but normal pyruvate dehydrogenase (PDH) activity (non-PDH; n = 35). We observed a strong positive association between L:P ratio and blood lactate in non-PDH CLA, whereas this association was weak in PDH-D CLA. Consequently, patient classification based on median L:P ratio showed improved diagnostic accuracy at higher lactate concentrations: for lactate <2.5 mmol/L the area under the ROC curve was not statistically different from 0.5 (P = 0.3), whereas it was statistically different for lactate >2.5 mmol/L. In the 2.5 to 5.0 mmol/L lactate category, the sensitivity and specificity at an optimal cut point of 18.4 were 93% (95% CI, 77%-99%) and 71% (95% CI, 20%-96%), respectively; for lactate >5.0 mmol/L, with an optimal cut point of 25.8, sensitivity and specificity were 96% (95% CI, 77%-99%) and 100% (95% CI, 59%-100%), respectively.

Conclusion: Usefulness of the L:P ratio for differentiating non-PDH and PDH-D types of CLA increases at higher lactate concentrations.

PubMed Disclaimer

LinkOut - more resources